Ask a Question
Coherent
Search Results
Refine
1 - 12 of 91 Products for 'j-10si-he' Page 1 of 8 |

j-10si-he

Quantum Series EnergyMax Sensors

Quantum Series EnergyMax Sensors

…as the average power of pulsed systems from the nanowatt to milliwatt level, across a broad range of wavelengths. Specifically, the J-10SI-LE and J-10SI-HE are both silicon photodiode based sensors with apertures of 10 mm and a spectral range of 325 nm to 900 nm, which measure down to 20 pJ and 200…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…measurements are still accurate when used at wavelengths different from the calibration wavelength. Table 2-5. Quantum EnergyMax Sensor Specifications J-10SI-HE Energy Range 750 pJ to 775 nJ (at 532 nm) Noise Equivalent Energy < 75 pJ (at 532 nm) Wavelength Range (nm) 325 to 900 Active Area Diameter…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…measurements are still accurate when used at wavelengths different from the calibration wavelength. Table 2-5. Quantum EnergyMax Sensor Specifications J-10SI-HE Energy Range 750 pJ to 775 nJ (at 532 nm) Noise Equivalent Energy < 75 pJ (at 532 nm) Wavelength Range (nm) 325 to 900 Active Area Diameter…

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

…Sensors 22 + 22 4 + 4 32 + 52 9 + 25 Measurement Accuracy = where U =`Percent Calibration Uncertainty'and W =`Wavelength Accuracy' Example 1 J-10SI-HE used at 355 nm U = 3% W = 5% Measurement Accuracy = = = 5.8% Example 2 J-10MB-LE used at 532 nm U = 2% W = 2% Measurement Accuracy = = = 2.8%…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…CrossReference Index Model Name Index DB-25 Energy Sensors USB/RS Energy Sensors DB-25 Power Sensors USB/RS Power Sensors Device Specifications Model J-10SI-HE J-10Ge-LE Energy Range 750 pJ to 775 nJ (at 532 nm) 1 nJ to 600 nJ (at 1064 nm) Noise Equivalent Energy (pJ) 4 mm at energies above 200 nJ…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…in.) 76.2 mm (3.0 in.) 50.8 mm (2.0 in.) 2X 4.57 mm (0.18 in.) Ø 10.0 mm (0.39 in.) Aperture Plate M6-6H THD 5.08 mm (0.2 in.) [5.08] and NO. 1/4-20 UNC-2B THD 5.08 mm (0.2 in.) for Mounting Sensor Adjustable 200.15 mm (7.88 in.) Max. 117.6 mm (4.63 in.) Min. 1/2-28 UNEF-2B J-10SI-HE Model J-10SI-HE

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…CrossReference Index Model Name Index DB-25 Energy Sensors USB/RS Energy Sensors DB-25 Power Sensors USB/RS Power Sensors Device Specifications Model J-10SI-HE J-10Ge-LE Energy Range 750 pJ to 775 nJ (at 532 nm) 1 nJ to 600 nJ (at 1064 nm) Noise Equivalent Energy (pJ) 4 mm at energies above 200 nJ…

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

…in.) 76.2 mm (3.0 in.) 50.8 mm (2.0 in.) 2X 4.57 mm (0.18 in.) Ø 10.0 mm (0.39 in.) Aperture Plate M6-6H THD 5.08 mm (0.2 in.) [5.08] and NO. 1/4-20 UNC-2B THD 5.08 mm (0.2 in.) for Mounting Sensor Adjustable 200.15 mm (7.88 in.) Max. 117.6 mm (4.63 in.) Min. 1/2-28 UNEF-2B J-10SI-HE Model J-10SI-HE

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…in.) 76.2 mm (3.0 in.) 50.8 mm (2.0 in.) 2X 4.57 mm (0.18 in.) Ø 10.0 mm (0.39 in.) Aperture Plate M6-6H THD 5.08 mm (0.2 in.) [5.08] and NO. 1/4-20 UNC-2B THD 5.08 mm (0.2 in.) for Mounting Sensor Adjustable 200.15 mm (7.88 in.) Max. 117.6 mm (4.63 in.) Min. 1/2-28 UNEF-2B J-10SI-HE Model J-10SI-HE

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

…in.) 76.2 mm (3.0 in.) 50.8 mm (2.0 in.) 2X 4.57 mm (0.18 in.) Ø 10.0 mm (0.39 in.) Aperture Plate M6-6H THD 5.08 mm (0.2 in.) [5.08] and NO. 1/4-20 UNC-2B THD 5.08 mm (0.2 in.) for Mounting Sensor Adjustable 200.15 mm (7.88 in.) Max. 117.6 mm (4.63 in.) Min. 1/2-28 UNEF-2B J-10SI-HE Model J-10SI-HE

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

…in.) 76.2 mm (3.0 in.) 50.8 mm (2.0 in.) 2X 4.57 mm (0.18 in.) Ø 10.0 mm (0.39 in.) Aperture Plate M6-6H THD 5.08 mm (0.2 in.) [5.08] and NO. 1/4-20 UNC-2B THD 5.08 mm (0.2 in.) for Mounting Sensor Adjustable 200.15 mm (7.88 in.) Max. 117.6 mm (4.63 in.) Min. 1/2-28 UNEF-2B J-10SI-HE Model J-10SI-HE

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…in.) 76.2 mm (3.0 in.) 50.8 mm (2.0 in.) 2X 4.57 mm (0.18 in.) Ø 10.0 mm (0.39 in.) Aperture Plate M6-6H THD 5.08 mm (0.2 in.) [5.08] and NO. 1/4-20 UNC-2B THD 5.08 mm (0.2 in.) for Mounting Sensor Adjustable 200.15 mm (7.88 in.) Max. 117.6 mm (4.63 in.) Min. 1/2-28 UNEF-2B J-10SI-HE Model J-10SI-HE

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions