Ask a Question
Coherent
Search Results
Refine
13 - 24 of 91 Products for 'j-10si-he' Page 2 of 8 |

j-10si-he

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…measurements are still accurate when used at wavelengths different from the calibration wavelength. Table 2-5. Quantum EnergyMax Sensor Specifications J-10SI-HE Energy Range 750 pJ to 775 nJ (at 532 nm) Noise Equivalent Energy < 75 pJ (at 532 nm) Wavelength Range (nm) 325 to 900 Active Area Diameter…

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

…Sensors 22 + 22 4 + 4 32 + 52 9 + 25 Measurement Accuracy = where U =`Percent Calibration Uncertainty'and W =`Wavelength Accuracy' Example 1 J-10SI-HE used at 355 nm U = 3% W = 5% Measurement Accuracy = = = 5.8% Example 2 J-10MB-LE used at 532 nm U = 2% W = 2% Measurement Accuracy = = = 2.8%…

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

…Sensors 22 + 22 4 + 4 32 + 52 9 + 25 Measurement Accuracy = where U =`Percent Calibration Uncertainty'and W =`Wavelength Accuracy' Example 1 J-10SI-HE used at 355 nm U = 3% W = 5% Measurement Accuracy = = = 5.8% Example 2 J-10MB-LE used at 532 nm U = 2% W = 2% Measurement Accuracy = = = 2.8%…

Book.book

Book.book

…EnergyMax series consists of three different models that provide very low pulse energy measurement down to 20 pJ. Two of the models (J-10SI-LE and J-10SI-HE) incorporate a Silicon photodiode, and one model (J-10GE-LE) incorporates a Germanium photodiode. All three models contain large 10 mm clear…

Book.book

Book.book

…EnergyMax series consists of three different models that provide very low pulse energy measurement down to 20 pJ. Two of the models (J-10SI-LE and J-10SI-HE) incorporate a Silicon photodiode, and one model (J-10GE-LE) incorporates a Germanium photodiode. All three models contain large 10 mm clear…

Book.book

Book.book

…EnergyMax series consists of three different models that provide very low pulse energy measurement down to 20 pJ. Two of the models (J-10SI-LE and J-10SI-HE) incorporate a Silicon photodiode, and one model (J-10GE-LE) incorporates a Germanium photodiode. All three models contain large 10 mm clear…

Book.book

Book.book

…EnergyMax series consists of three different models that provide very low pulse energy measurement down to 20 pJ. Two of the models (J-10SI-LE and J-10SI-HE) incorporate a Silicon photodiode, and one model (J-10GE-LE) incorporates a Germanium photodiode. All three models contain large 10 mm clear…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…of the optic and the absorption of the coating, and is normalized to the calibration wavelength. J-25MUV-193 ± 3% 193 nm J-50MUV-248 ± 4% 248 nm J-10SI-HE ± 5% 532 nm Table 3-4. Wavelength Compensation Accuracy (Sheet 2 of 2) Sensor Wavelength Compensation Accuracy (%) (for wavelengths other than…

Book.book

Book.book

…numbers and then taking the square root: Measurement Accuracy = where U = 'Percent Calibration Uncertainty' and W = 'Wavelength Accuracy' Example 1 J-10SI-HE used at 355 nm U = 3% W = 5% Measurement Accuracy = = = 5.8% Example 2 J-10MB-LE used at 532 nm U = 2% W = 2% Measurement Accuracy = = = 2.8%…

Book.book

Book.book

…± 2% 1064 nmAll High Rep. Rate sensors (Diffuse metallic coating) ± 3% J-50MB-YAG ± 2% J-50MB-IR ± 3% 1064, 2940 nm J-25MB-IR ± 4% 1064 nm J-25MUV-193 ± 3% 193 nm J-25MUV-248 ± 3% 248 nm J-50MUV-193 ± 4% 193 nm J-50MUV-248 ± 4% 248 nm J-10SI-LE ± 5% 532 nm J-10SI-HE ± 5% J-10GE-LE ± 5% 1064 nm

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

…of the optic and the absorption of the coating, and is normalized to the calibration wavelength. J-25MUV-193 ± 3% 193 nm J-50MUV-248 ± 4% 248 nm J-10SI-HE ± 5% 532 nm Table 3-4. Wavelength Compensation Accuracy (Sheet 2 of 2) Sensor Wavelength Compensation Accuracy (%) (for wavelengths other than…

Book.book

Book.book

…numbers and then taking the square root: Measurement Accuracy = where U = 'Percent Calibration Uncertainty' and W = 'Wavelength Accuracy' Example 1 J-10SI-HE used at 355 nm U = 3% W = 5% Measurement Accuracy = = = 5.8% Example 2 J-10MB-LE used at 532 nm U = 2% W = 2% Measurement Accuracy = = = 2.8%…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions