Ask a Question
Coherent

Search Results

Refine

Result Type

37 - 48 of 141 Products for 'j 10mb le' Page 4 of 12 |
Related Categories: J-10mb-le | J-50mb-le | J 50mb He | Sensor J25 | J10mb He

j 10mb le

2010-2011-Laser-Measurement-and-Control-Catalog.pdf

2010-2011-Laser-Measurement-and-Control-Catalog.pdf

54 Superior Reliability & Performance · www.Coherent.com · LMC.sales@coherent.com POWER & ENERGY Power Sensors Energy Sensors Custom & OEM BEAM DIAGNOSTICS CALIBRATION & SERVICE Power & Energy Meters Overall measurement accuracy is a combination of calibration uncertainty (found…

Book.book

Book.book

EnergyMax Sensors User Manual 22 Use of EnergyMax sensors at average power levels beyond the base model average power specification--without the optional heat sink--may cause permanent damage to the sensor. Table 11. Average Power Ratings SENSOR MODEL APERTURE (MM) WAVELENGTH (NM) NO HEAT SINK (W)…

Book.book

Book.book

Technical Description 15 The EnergyMax sensor line uses a pyroelectric element to measure the energy in a laser pulse. It does this by producing a large electrical charge for a small change in temperature. The active sensor circuit takes the current from the sensor element and converts it to a…

Book.book

Book.book

EnergyMax-USB/RS User Manual 18 output will be automatically compensated. Wavelength compensation results in an additional error factor when engaged and when the sensor is being used at a wavelength different from the wavelength at which it was calibrated. The accuracy is based upon the sensor…

Book.book

Book.book

EnergyMax Sensors User Manual 22 Use of EnergyMax sensors at average power levels beyond the base model average power specification--without the optional heat sink--may cause permanent damage to the sensor. Table 11. Average Power Ratings SENSOR MODEL APERTURE (MM) WAVELENGTH (NM) NO HEAT SINK (W)…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

Technical Description 3 - 3 The EnergyMax sensor line uses a pyroelectric element to measure the energy in a laser pulse. It does this by producing a large electrical charge for a small change in temperature. The active sensor circuit takes the current from the sensor element and converts it to a…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual 3 - 6 output will be automatically compensated. Wavelength compensation results in an additional error factor when engaged and when the sensor is being used at a wavelength different from the wavelength at which it was calibrated. The accuracy is based upon the sensor…

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

EnergyMax-USB-RS-Sensors-Guide FORMFIRST.pdf

7· Toll Free: (800) 343-4912 · Tel: (408) 764-4042 · Fax: (503) 454-5727 Overall measurement accuracy is a combination of calibration uncertainty (found in the sensor specification tables) and the wavelength compensation accuracy (found in the"Wavelength Compensation Accuracy" table, below). The…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

Technical Description 3 - 3 The EnergyMax sensor line uses a pyroelectric element to measure the energy in a laser pulse. It does this by producing a large electrical charge for a small change in temperature. The active sensor circuit takes the current from the sensor element and converts it to a…

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual

EnergyMax-USB/RS User Manual 3 - 6 output will be automatically compensated. Wavelength compensation results in an additional error factor when engaged and when the sensor is being used at a wavelength different from the wavelength at which it was calibrated. The accuracy is based upon the sensor…

Book.book

Book.book

EnergyMax Sensors User Manual 22 Use of EnergyMax sensors at average power levels beyond the base model average power specification--without the optional heat sink--may cause permanent damage to the sensor. Table 11. Average Power Ratings SENSOR MODEL APERTURE (MM) WAVELENGTH (NM) NO HEAT SINK (W)…

Book.book

Book.book

…2% ± 2% ± 2% ± 2% Linearity (%) Refer to "Measurement Linearity" on page 25. Cable Length (m) 2.5 2.5 2.5 2.5 2.5 2.5 Cable Type J DB-25 J DB-25 J DB-25 J DB-25 J DB-25 J DB-25 Item Number 1110573 1110576 1110746 1110743 1110843 1110855 a. The maximum average power specification in the table above…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.