1 - 10 of 24 Search Results for j4
|
|
|
1.
Small-Area BNC Terminated Energy Sensors
|
|
... Sensors include an integrated, fast pre-amplifier circuit, and are optimized for measuring low-energy, high repetition rate lasers. The J3- and J4- models utilize a pyroelectric detector, while the J3S-10 is based upon a silicon detector. All sensors are EMI-shielded and contain a noise-free, ...
Related Searches: j3s-10 | j3-05 | j4-09
|
|
|
|
|
3.
Small-Area BNC Terminated Energy Sensors
|
|
... ; Sensors include an integrated, fast pre-amplifier circuit, and are optimized for measuring low-energy, high repetition rate lasers. The J3- and J4- models utilize a pyroelectric detector, while the J3S-10 is based upon a silicon detector. All sensors are EMI-shielded and contain a noise-free ...
Related Searches: j309 | j3s | fast photodiode | j3s-10
|
|
|
|
4.
ACF2A09
(PAGE 3 OF 20)
|
|
|
... , such as the J3S-10 Silicon Joulemeter. This extremely sensitive Joulemeter measures energy levels from subpicojoules to nanojoules. The J3 and J4 series probes are useful if you need a broad spectral response UV to Far IR in the microjoule to millijoule range. Our high sensitivity probes possess excellent ...
|
|
|
|
5.
ACF2A09
(PAGE 4 OF 20)
|
|
|
... of the faster heat transfer and significant decrease in the pyroelectric time constant, the HR probes measure pulses as fast as 20,000 pps. The J3/J4/J3S series are high sensitivity Joulemeters combining a Pyroelectric (J3/J4) or Silicon (J3S) detector with a fast transistor amplifier circuit. These ...
|
|
|
|
6.
ACF2A09
(PAGE 5 OF 20)
|
|
... line indicates an uncalibrated portion of the spectral curve.) Note: "-3" models are spectral responses with their quartz windows removed. J4-05, J4-09, J8LP, J9LP, J25, J25LP, J50, J50LP, J100 J3-02, J3-05, J3-09, J25LP-3, J50LP-3, J25HR, J50HR J3S-05, J3S-10 JMAX43, JMAX11 Safe Operation ...
Related Searches: molectron j50 | molectron j25
|
|
|
|
7.
ACF2A09
(PAGE 6 OF 20)
|
|
... Flat Black 9 mm ±2% J25LP-1 J25LP-2(4) J25 J3S-10 J8LP J9LP J25LP-3(4) J50 J3-02 JMAX43 J3-05 J50LP-1 J50LP-2(4) J25HR J3-09 J50LP-3(4) J50HR J4-05 JMAX11 J100 J4-09 Low Profile Probes Large Area Probes High Sensitivity Probes Instrument Model No. J3S-10 J3-02, -05, -09 J4-05 J4-09 J25 J50 J25HR, J25LP ...
Related Searches: om4001
|
|
|
|
8.
ACF2A09
(PAGE 7 OF 20)
|
|
|
Probe Specifications J100JMAX43 25.4 mm J8LP/JMAX11 J50LP J25/J25HR J9LP JS50 Beamsplitter J25LP JS25 Beamsplitter J50/J50HR J3/J4/J3S 70 mm 70 mm 23 mm 14 mm 15.2 mm 14 mm 15.9 mm 25 mm25 mm 12 mm 58.4 mm27.9 mm 58.4 mm 76.2 mm 50 mm 38.1 mm 108 mm 44.5 mm 5 mm /10 mm diameter aperture 25.4 mm 50 ...
|
|
|
|
10.
ACF2A09
(PAGE 8 OF 20)
|
|
|
... attach directly to the probe and expose it to <10% of the laser energy. Model JS25Q is a easy-to-install inline beamsplitter designed for the J3, J4, and J3S Joulemeter probes. Model JS25/JS50Q-1 is designed for the J25 or J50 Pyroelectric Joulemeter probes. Model JS25/JS50Q-2 is designed for the ...
|
|