1Large-Area Energy Sensors (50 mm)
... iat very high pulse repetition rates. Sensors with an LP in the product name are low profile, working well in tight spaces.  The J50LP-2, J50LP-3 and J50LP-3 all have an integral UV quartz diffuser; this provides some laser attenuation and beam spreading , thus extending their pulse energy ...
Related Searches: j50 | j50hr | j-50 | j50-lp

2[index.cfm?fuseaction=interfaces.TechNote&TNID=171]
... EnergyMax     J3 Series J4 Series J5 Series J8LP, J9LP J8LP-4 J25, J50, J100 J25HR, J50HR J25LP-1, 1A, 2, 2A J50LP-1, 1A, 2, 2A J25LP-3, 4 J50LP-3, 4 J25LP-3A, 4A J50LP-3A, 4A J25LP-3A-2K, 4A-2K J50LP-3A-2K, 4A-2K J25LP-MB         J45LP-MB         J25LP ...
Related Searches: epm 2000 | j25lp-1

3pdf document  ACF2A09 Best match in this PDF  |  All matches in this PDF
® Laser Energy s a growing, customer driven Electro-Optics manufacturer located in the heart of the Silicon Forest, Portland, Oregon, we take great pride in our history as a technology leader in Thermal Detectors, Laser Power and Energy Probes, Joulemeters and Power Meters, dating back to 1970. Alexandrite ...
Related Searches: jmax43 | j100 | j25lp-1 | jd501

4pdf document  ACF2A09  (PAGE 5 OF 20)
... ;J50LP-2 have a UV quartz diffuser providing some laser attenuation and beam spreading, thus extending their pulse energy range. The J25LP-3 & J50LP-3 measure pulses as fast as 20,000 pps on an oscilloscope. The J25LP-Ruby and J25LP-Erbi are low profile detectors designed to measure ruby or erbium ...
Related Searches: jmax43 | molectron j50

5pdf document  ACF2A09  (PAGE 6 OF 20)
... 300 100 µs Spectrally Flat Black 9 mm ±2% J25LP-1 J25LP-2(4) J25 J3S-10 J8LP J9LP J25LP-3(4) J50 J3-02 JMAX43 J3-05 J50LP-1 J50LP-2(4) J25HR J3-09 J50LP-3(4) J50HR J4-05 JMAX11 J100 J4-09 Low Profile Probes Large Area Probes High Sensitivity Probes Instrument Model No. J3S-10 J3-02, -05, -09 J4-05 J4 ...