Ask a Question
Coherent
Search Results
1 - 12 of 195 Products for 'kw fiber laser' Page 1 of 17 |

kw fiber laser

HighLight-FL-Series-Multi-kW.pdf

HighLight-FL-Series-Multi-kW.pdf

…©2015 Coherent, Inc. Industrial Multi kW Fiber Laser HighLight FL-Series INVISIBLE AND/OR VISIBLE LASER RADIATION. AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION. CLASS IV LASER PRODUCT PER EN60825-1 (2007) FIBER LASER 1100 nm ±20 nm 2 kW MAX. CW DIODE LASER 635 nm 1 mW MAX. CW

Microsoft Word - kW Thermopile Damage Threshold.doc

Microsoft Word - kW Thermopile Damage Threshold.doc

…per minute Laser Beams with near-Gaussian Profiles The sensor is most susceptible to damage from laser beams that approach a Gaussian profile. Coherent has performed finite element analysis (FEA) thermal modeling on the PMmodel kW sensors, followed by live testing of a fiber laser that is nearly…

COHR PowerMax-Pro kW DS 0317 4 FINAL.pdf

COHR PowerMax-Pro kW DS 0317 4 FINAL.pdf

…with a direct QBH fiber adapter option 100% of the light is captured, resulting in a Class 1 measurement system. The new PowerMax-Pro kW models will be particularly useful for welding, cutting, drilling, and engraving with high power fiber lasers, CO2 lasers, or solid state lasers. FEATURES · Very…

Laser Focus World - January 2015

Laser Focus World - January 2015

…while the 50 mm-mrad applications typically are brazing, heat treating, and laser metal deposition." Wavelengths in the "9xx" nm wavelength range are slightly shorter than those of traditional 1 µm lasers such as disk, fiber, and Nd:YAG. These shorter wavelengths allow better absorption in highly…

HighLight-FL-Series-Multi-kW.pdf

HighLight-FL-Series-Multi-kW.pdf

…in.) 584.2 mm (23.0 in.) 817.9 mm (32.2 in.) 998.2 mm (39.3 in.) 871.2 mm (34.3 in.) Industrial Multi kW Fiber Laser HighLight FL-Series Mechanical Specifications Fiber Laser Module 2 to 3 kW Fiber Laer System Left Side View Front View Top View Side View Top View Front View Rear View Right Side View

HighLight-FL-Series-Multi-kW.pdf

HighLight-FL-Series-Multi-kW.pdf

…3000FL Laser Output Power (kW) 2 3 Wavelength (nm) 1080 ±10 Operation Mode CW and modulated Modulation Frequency (Hz) 10k (max.) Power Stability (% over 8 hours) <2 Fiber Diameter (m) 100 (others on request) Beam Quality1 (mm
*mrad ) 5 Beam Share Options 2 way time share Delivery Fiber Options2…

HighLight-FL-Series-Multi-kW.pdf

HighLight-FL-Series-Multi-kW.pdf

…©2015 Coherent, Inc. Industrial Multi kW Fiber Laser HighLight FL-Series INVISIBLE AND/OR VISIBLE LASER RADIATION. AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION. CLASS IV LASER PRODUCT PER EN60825-1 (2007) FIBER LASER 1100 nm ±20 nm 2 kW MAX. CW DIODE LASER 635 nm 1 mW MAX. CW

Microsoft Word - kW Thermopile Damage Threshold.doc

Microsoft Word - kW Thermopile Damage Threshold.doc

…per minute Laser Beams with near-Gaussian Profiles The sensor is most susceptible to damage from laser beams that approach a Gaussian profile. Coherent has performed finite element analysis (FEA) thermal modeling on the PMmodel kW sensors, followed by live testing of a fiber laser that is nearly…

HighLight-FL-Series-Multi-kW.pdf

HighLight-FL-Series-Multi-kW.pdf

…3000FL Laser Output Power (kW) 2 3 Wavelength (nm) 1080 ±10 Operation Mode CW and modulated Modulation Frequency (Hz) 10k (max.) Power Stability (% over 8 hours) <2 Fiber Diameter (m) 100 (others on request) Beam Quality1 (mm
*mrad ) 5 Beam Share Options 2 way time share Delivery Fiber Options2…

Microsoft Word - kW Thermopile Damage Threshold.doc

Microsoft Word - kW Thermopile Damage Threshold.doc

…per minute Laser Beams with near-Gaussian Profiles The sensor is most susceptible to damage from laser beams that approach a Gaussian profile. Coherent has performed finite element analysis (FEA) thermal modeling on the PMmodel kW sensors, followed by live testing of a fiber laser that is nearly…

COHR PowerMax-Pro kW DS 0317 4 FINAL.pdf

COHR PowerMax-Pro kW DS 0317 4 FINAL.pdf

…with a direct QBH fiber adapter option 100% of the light is captured, resulting in a Class 1 measurement system. The new PowerMax-Pro kW models will be particularly useful for welding, cutting, drilling, and engraving with high power fiber lasers, CO2 lasers, or solid state lasers. FEATURES · Very…

COHR PowerMax-Pro kW DS 0417 5 FINAL.pdf

COHR PowerMax-Pro kW DS 0417 5 FINAL.pdf

…with a direct QBH fiber adapter option 100% of the light is captured, resulting in a Class 1 measurement system. The new PowerMax-Pro kW models will be particularly useful for welding, cutting, drilling, and engraving with high power fiber lasers, CO2 lasers, or solid state lasers. FEATURES · Very…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions