Search Results

Refine
25 - 31 of 31 Products for 'kw power meter' Page 3 of 3 |

kw power meter

LabMax-Pro SSIM User Manual

LabMax-Pro SSIM User Manual

…shape and peak power of modulated lasers with
pulse lengths greater than 10 µs. These pulses can be integrated to
calculate individual pulse energy.
Applying
Wavelength
Compensation
Accuracy
Overall measurement accuracy is a combination of the meter and
sensor…

COHR HighLightFL Compact MultiMode DS 0818.pdf

COHR HighLightFL Compact MultiMode DS 0818.pdf

…100 µm fiber
Power Stability (%) ± 2
Pulse Frequency Range CW to 5 kHz
Wavelength (nm) 1070 ± 10
ELECTRICAL RATINGS
Voltage 3 x 230/400 V ±10% or 3 x 277/480 V ±10%; 50/60 Hz; PE
Connected Load (kVA) 19.2
Effective Power at Nominal Power (kW) 17.9
Max. Current…

COHR HighLightFL Standard FFC DS 0818.pdf

COHR HighLightFL Standard FFC DS 0818.pdf

…on request)
Power Stability (%) ± 2
Pulse Frequency Range CW - 5 kHz
Wavelength (nm) 1070 ± 10
ELECTRICAL RATINGS
Voltage 3 x 230 / 400 V ± 10% or 3 x 277 / 480 V ± 10%; 50/60 Hz; PE
Connected Load (kVA) 19.2
Effective Power at Nominal Power (kW) 17.9
Max.…

COHR HighLightFL Compact SingleMode DS 0818.pdf

COHR HighLightFL Compact SingleMode DS 0818.pdf

…mrad
Power Stability (%) ± 2
Pulse Frequency Range CW - 5 kHz
Wavelength (nm) 1070 ± 10
ELECTRICAL RATINGS
Voltage 3 x 230 / 400 V ± 10% or 3 x 277 / 480 V ± 10%; 50/60 Hz; PE
Connected Load (kVA) 2.1 2.9 3.6 5 6.6 7.2
Effective Power at Nominal Power (kW) 2 2.7…

COHR HighLightFL Standard FFS DS 0818.pdf

COHR HighLightFL Standard FFS DS 0818.pdf

…µm fiber
Power Stability (%) ± 2
Pulse Frequency Range CW to 5 kHz
Wavelength (nm) 1070 ± 10
ELECTRICAL RATINGS
Voltage 3 x 230/400 V ±10% or 3 x 277/480 V ±10%; 50/60 Hz; PE
Connected Load (kVA) 9.8 12.7 14.5
Effective Power at Nominal Power (kW) 9.1 11.8 13.5…

Photonics Spectra - July 2014

Photonics Spectra - July 2014

…measurement instrumentation at Coherent Inc.,
and is responsible for market development of
the company's range of laser power and energy
meters; email: sean.bergman@coherent.com.
Figure 5. Thin-film thermoelectric sensors are available with a broadband coating, which operates…

ILS Annealing.PDF

…desired melt characteristics for LTPS, this means that laser
power must also increase, assuming that the laser line length
is scaled up with the panel dimensions.
The Coherent VYPER lasers used for LTPS are powerful
excimer lasers, with pulse energies as high as 2J. This energy…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions