labmax

LabMax Meters DS

LabMax Meters DS

…and Energy Meters Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice. Coherent's LabMax meters are compliant with the EU Restriction of Hazardous Substances (RoHS) and Waste Electrical and Electronic Equipment [WEEE] Directives. They…

LabMax UserManualAddendum V00-63-41 .fm

LabMax UserManualAddendum V00-63-41 .fm

LabMax User Manual Addendum Page 5 of 16 GPIB CommunicationMode Valid inputs are 1 to 31. Address 0 is reserved for the GPIB controller-in-charge board. The assigned number must match whatever is currently set in the meter hardware. RS232 CommunicationMode Valid inputs are 1 to 9, depending on which…

LabMax UserManualAddendum V00-63-41 .fm

LabMax UserManualAddendum V00-63-41 .fm

LabMax User Manual Addendum Page 6 of 16 RS232Settings The RS232Settings property specifies the serial port settings of the addressed meter. It uses the same specification format as the MSCOMM32 control settings property. Basically, it is a string composed of four settings and has the following…

LabMax UserManualAddendum V00-63-41 .fm

LabMax UserManualAddendum V00-63-41 .fm

LabMax User Manual Addendum Page 7 of 16 Inputs: iMeterIndex--valid parameter values depend on the communication mode. For more information, refer to "Detailed Reference" on page 4. iRS232Settings--a BSTR holding the serial port settings string, as defined above. Because this property takes an input…

LabMax UserManualAddendum V00-63-41 .fm

LabMax UserManualAddendum V00-63-41 .fm

LabMax User Manual Addendum Page 9 of 16 HRESULT SendCommandOrQuer ([in] SHORT iMeterIndex, [in] BSTR iCommandOrQuery, [out,retval] SHORT
* oResult) Inputs: iMeterIndex--valid parameter values depend on the communication mode. For more information, refer to "Detailed Reference" on page 4.…

LabMax UserManualAddendum V00-63-41 .fm

LabMax UserManualAddendum V00-63-41 .fm

LabMax User Manual Addendum Page 10 of 16 ConnectToMeter The ConnectToMeter method connects to the addressed meter if the communication mode is RS-232 or GPIB. If the communication mode is RS-232, it uses the settings as defined by the RS232Settings property. If the communication mode is USB, this…

LabMax UserManualAddendum V00-63-41 .fm

LabMax UserManualAddendum V00-63-41 .fm

LabMax User Manual Addendum Page 12 of 16 USBStreamingPacket The USBStreamingPacket event fires when a streaming measurement data packet is generated by the meter. This event only occurs if the communication mode is USB. void USBStreamingPacket ([in] SHORT iMeterIndex, [in] VARIANT iStreamingPacket)…

LabMax UserManualAddendum V00-63-41 .fm

LabMax UserManualAddendum V00-63-41 .fm

LabMax User Manual Addendum Page 13 of 16 Pulsed Thermopile Joules Mode (for long-pulsed lasers only) When a thermopile sensor is attached, the meter has the capability of measuring energy from a finite duration laser pulse, or from a series of finite duration laser pulses. (Thermopile sensors are…

LabMax UserManualAddendum V00-63-41 .fm

LabMax UserManualAddendum V00-63-41 .fm

LabMax User Manual Addendum Page 14 of 16 Thermopile Sensors, Long Pulse Joules Connecting a thermopile sensor to the meter and switching to Joules mode displays the screen shown below. This mode measures the energy of single pulses between 1 millisecond and 10 seconds in length, and with energies…

LabMax UserManualAddendum V00-63-41 .fm

LabMax UserManualAddendum V00-63-41 .fm

LabMax User Manual Addendum Page 15 of 16 Once the calculation has been completed, the new Joules value is displayed, the CALCULATING indicator is replaced with READY, and the plot stops (see the following figure). At this point, the meter is ready to receive another pulse. Soft Keys There are three…

LabMax UserManualAddendum V00-63-41 .fm

LabMax UserManualAddendum V00-63-41 .fm

LabMax User Manual Addendum Page 5 of 16 GPIB CommunicationMode Valid inputs are 1 to 31. Address 0 is reserved for the GPIB controller-in-charge board. The assigned number must match whatever is currently set in the meter hardware. RS232 CommunicationMode Valid inputs are 1 to 9, depending on which…

LabMax UserManualAddendum V00-63-41 .fm

LabMax UserManualAddendum V00-63-41 .fm

LabMax User Manual Addendum Page 6 of 16 RS232Settings The RS232Settings property specifies the serial port settings of the addressed meter. It uses the same specification format as the MSCOMM32 control settings property. Basically, it is a string composed of four settings and has the following…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.