Search Results

25 - 36 of 56 Products for 'laser chiller' Page 3 of 5 |

laser chiller

Vitara Preinstall.book

Vitara Preinstall.book


System Chiller [ ] Distilled water available on-site (~2 liters).
Laser Safety
[ ] Laser Safety Officer (LSO) identified (recommended).
[ ] Laser Safety Training completed.
[ ] Laser controlled area established.
[ ] Personal protective equipment (Laser safety eyewear)…

COHR HyperRapidNX DS 0618 1.pdf

COHR HyperRapidNX DS 0618 1.pdf

…Mounting Orientation Horizontal
Chiller Water-to-Air or Water-to-Water
Dimensions
Laser Head
Power Supply
SMC Chiller
600 x 780 x 245 mm
3U 19" rack
500 x 317 x 615 mm
Weight
Laser Head
Power Supply
SMC Chiller
67 kg
16 kg
43…

UCLD Catalog.book

UCLD Catalog.book

…maintenance and troubleshooting including the chiller.
Key Topics: Laser and electrical safety, theory of operation, proper installation and first-time setup; turn-on and
off procedures; laser optimization; monitoring fast photo diode output; chiller fluid and filter replacement; fault…

Libra PreInstallation.book

Libra PreInstallation.book

…humidity in specification.

Laser area layout planned according to system dimensions.
See "Utility and Environmental Requirements" on page 3-2.
Receive and
Inspect

Area is clean and large enough to uncrate the laser, power
supplies and chiller.
See "Receiving and

COHR Azure DS 0717 4.pdf

COHR Azure DS 0717 4.pdf


Laser Head Closed-loop chiller for baseplate
Power Supply Air-cooled
Shipping Thermal Requirements -20 to +50°C shipping in a non-condensing environment
Orientation Horizontal ±2°
Power Supply (VAC) 100 to 240
Azure Power Consumption (kW) 1
Chiller Power…

MetaBEAM1000c Pre.book

MetaBEAM1000c Pre.book


The chiller temperature should never be set below the ambient
dew point. Operating in this condition can cause condensation
that will permanently damage the laser tube. Damage caused by
condensation is not covered under warranty.
Table 1-4. Chiller Requirements
CHILLER

COHR Vitara DS 0416revC 3.pdf

COHR Vitara DS 0416revC 3.pdf

…Electrical and Cooling Requirements
Voltage 100 to 240
Current Max. (A) 5
Line Frequency (Hz) 50 to 60
Cooling Closed-cycle chiller
Laser Head Dimensions (L x W x H) 609.6 x 427.5 x 162.4 mm (24.0 x 16.8 x 6.4 in.) excluding handles
Beam Height 120.6 mm (4.75 in.)

Biosafety Level 3 setup for multiphoton microscopy in vivo

Biosafety Level 3 setup for multiphoton microscopy in vivo

…of the laser head to the chiller by passing through the wall
of the power supply BSC. (c,d) The laser head BSC sits on top of an optical table through the use of 3 custom
made self-sealing feet that transverse the BSC to prevent its deformation overtime due to the weight of the laser

COHR MephistoMOPA DS 0417 2.pdf

COHR MephistoMOPA DS 0417 2.pdf

…kg (9.3 lbs.)
Laser Controller Amplifier Weight2 11.9 to 13.1 kg (26.2 to 28.9 lbs.)
Laser Head Cooling3 Water cooling
Water Flow Rate (l/min.) >3
Water Pressure at Laser Head (bar) <4
Water Temperature4 (°C) 25
Cooling Power2 (W) (chiller) 300 to 600
Options…

PaladinAdvanced355 Datasheet 2017.pdf

PaladinAdvanced355 Datasheet 2017.pdf

…x L)
Laser Head 305 x 200 x 1100 mm (12 x 7.9 x 43.3 in.) +300 mm for fibers & connectors
Power Supply (master & slave) 482 x 177 x 505 mm (19 x 7 x 19.9 in.), 19 in., rack-mountable
Chiller (8W/10W) 482 x 177 x 560 mm (19 x 7 x 22 in.), 19 in., rack-mountable
Chiller

COHR RLScatalog 2017revA web.pdf

COHR RLScatalog 2017revA web.pdf

…Horizontal Horizontal Horizontal
Voltage 100 to 240
Current Max. (A) 5
Line Frequency (Hz) 50 to 60
Cooling Closed-cycle chiller
Laser Head Dimensions (L x W x H) 609.6 x 427.5 x 162.4 mm (24.0 x 16.8 x 6.4 in.)
excluding handles
Beam Height 120.6 mm (4.75 in.)…

PaladinAdvanced355 DS

PaladinAdvanced355 DS


Weights
Laser Head 50 kg (110 lbs.)
Power Supply 30 kg (66 lbs.)
Chiller 38 kg + 3 liters coolant (84 lb. + 0.7 gal.)
Utility and Environmental
Requirements
PaladinTM Advanced 532
Mode Locked Laser
1 Fixed power.
2 Relative to laser mount.
3…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions