Search for Lasers, Laser Systems, Laser Measurment, Laser Service Coherent Inc., Worldwide websites Coherent Inc., calendar of events Coherent Inc., office locator Coherent Inc., Service Centers
     > Search
Search Coherent
Coherent Inc.
Superior Reliability & Performance
  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
Please enter a search phrase.

1 - 10 of 457 Search Results for m2
Search Suggestions: coherence length | numerical aperture | prism | 630nm | laser diode | avia-266 | picosecond laser | via

1pdf document  AVIA_355-23_DS_final  (PAGE 2 OF 2)
... Average Power Stability <2% (1) over 8 hours Average Output Power (W) 23 at 90 kHz Polarization Ratio2 >100:1 Horizontal Spatial Mode2 TEM00 (M2 <1.3) Beam Divergence Full Angle2 (mrad) <0.3 Beam Pointing Drift3 (rad/C) <25 1/e2 Beam Diameter2 (mm) 3.5 10% Beam Circularity >85% Warm ...

2pdf document  AVIA_355-23_DS_final  (PAGE 2 OF 2)
... Average Power Stability <2% (1 ) over 8 hours Average Output Power (W) 23 at 90 kHz Polarization Ratio2 >100:1 Horizontal Spatial Mode2 TEM00 (M2 <1.3) Beam Divergence Full Angle2 (mrad) <0.3 Beam Pointing Drift3 (rad/C) <25 1/e2 Beam Diameter2 (mm) 3.5 10% Beam Circularity >85% Warm ...

3pdf document  Sapphire561final  (PAGE 2 OF 2)
... . Printed in the U.S.A. MC-008-09-0M0109 Copyright 2009 Coherent, Inc. Wavelength1 (nm) 560 2 Output Power2 (mW) 50, 75, 100, 150 Spatial Mode TEM00, M2 <1.1 Beam Asymmetry 0.9 to 1.1 Beam Diameter at 1/e2 0.70 0.05 mm Beam Divergence (mrad) <1.3 Pointing Stability (over 2 hours after warm-up and ...

4pdf document  COHR_RLS2009_catalog  (PAGE 55 OF 76)
... E-2 Engine, the high-performance, high-reliability, regenerative amplifier module provides highest energy and efficiency with improved beam quality (M2 <1.3) Thermally stabilized amplifier platform Pulse energy to >3.5 mJ at 800 nm <50 fs and <100 fs pulse widths available Stability to ...

5pdf document  LegendP_DSrevB  (PAGE 2 OF 2)
... Ratio3 >1000:1 pre-pulse >100:1 post-pulse Energy Stability4 (RMS)(8 hours) <1% Beam Diameter (mm)(nominal) 10 1/e2 Spatial Mode TEM00, M2 <1.5 Polarization linear, horizontal Transform Limit5 1.5 times Pump Laser Evolution-15 Evolution-30 LegendTM Picosecond Ti:Sapphire Regenerative Amplifier ...

6pdf document  Sabre_Preinstallation Best match in this PDF  |  All matches in this PDF
Preinstallation Manual The Coherent InnovaŽ SabreTM Ion Laser 5100 Patrick Henry Drive Santa Clara, CA 95054 Innova Sabre Ion Laser ii This document is copyrighted with all rights reserved. Under the copyright laws, this document may not be copied in whole or in part or reproduced in any other media ...
Related Searches: innova 70 user manual | laser safety signs | innova 90 manual | innova 300 manual

7pdf document  Talisker_Glass_Micromachining Best match in this PDF  |  All matches in this PDF
Micromachining of Glass Using a Fiber-Based, High Average Power Picosecond Laser 1 Micromachining of Glass Using a Fiber-Based, High Average Power Picosecond Laser 1. Introduction Lasers are well established in many industries due to advantages such as the non-contact nature of the laser-material interaction ...
Related Searches: picosecond laser | glasses

8DIAMOND CO2 Applications Overview
2 Laser Applications Overview DIAMOND CO2 Applications Overview"> DIAMOND CO2 Applications Overview CO 2 Laser Applications Overview DIAMOND CO 2 Lasers: C-Series E-Series G-Series GEM-Series K-Series Applications Overview The application matrix below illustrates both materials and processes ...
Related Searches: gem laser co2 | co2 | thz generation

9pdf document  COHR_LifeSciencesGuide2009  (PAGE 51 OF 60)
... @ 1080 nm Tuning Speed2 (nm/s) >35 >40 Pulse Width1,3 (fs) 140 Noise1, 4 (%) <0.15 Output Power Stability1,5 <0.5 Spatial Mode1 TEM00 (M2 <1.1) Beam Diamater1,6 (mm) 1.2 0.2 Beam Ellipticity1,7 0.9 to 1.1 Astigmatism1 (%) <10 Repetition Rate (MHz) 80 Polarization Horizontal >500 ...

10pdf document  pdf_130  (PAGE 3 OF 8)
... up to 25 000 pulses, shown in Fig. 6. At the maximum, an index change of 8x10- 4 was measured, obtained with a total dose of 2 . 5 k J / c m2. This compares favorably with what is known about index changes inducible by longer-wavelength radiation which t u rn out to be about an order of magnitude s ...
Related Searches: lpx 210i | lpx210i


Page 1 2 3 4 5 6 7 8 9 10 11>> of 46 | Next


Site Search by  Site Search powered by SLI Systems