1 - 10 of 37 Search Results for methanol
|
|
1.
OpticallyPumpedLaser
(PAGE 10 OF 10)
|
|
|
... relations," Proc. IRE, 44, 904 (1956) 4 J. Farhoomand, and H. M. Pickett, "Stable 1.25 Watts cw Far Infrared Laser Radiation at the 119 µm Methanol Line," Int. J. of IR & MMW, 8(5), 441 (1987) 5 E. R. Mueller, W. E. Robotham, Jr., R. P. Meisner, R. A. Hart, J. Kennedy, and L. A. Newman ...
|
|
|
|
|
2.
Optic Transport Fiber (Fiber Optic) Cleaning
|
|
... or scratched easily. Wear finger cots, or powder free surgical gloves, while handling fiber optic cables. Only fresh (dry) spectroscopic grade Methanol should be used as a cleaning solvent. Do not use Acetone as a cleaning solvent on the fiber optical surfaces. It will dissolve the matrix which supports ...
Related Searches: fap | fap-i | fiber laser
|
|
|
|
|
3.
Cleaning Mounted Optics
|
|
... contact the optic. Fold this strip upon itself twice and grasp near the fold with clean hemostats as shown in the figure below. Place a few drops of Methanol on the fold and shake off the excess. Make a single swipe across the surface of the optic. Do not re-use the lens tissue as particles of dust ...
Related Searches: cleaning optics | optics
|
|
|
|
|
4.
Cleaning Removed Optics
|
|
... if applicable. Turn off the laser system, or block the pump laser beam if the optic to be cleaned is in an oscillator or amplifier. Place a drop of Methanol in the center of a lens tissue. Place the wet portion of the lens tissue on the optic surface and slowly drag it across the optic. The lens tissue ...
Related Searches: cleaning optics | optics
|
|
|
|
|
6.
Multiline High Reflector Cleaning
|
|
... edge. Never touch the optical surfaces with your bare skin, the hemostats, or materials other than lens tissue. Only fresh (dry) spectroscopic grade Methanol should be used to clean optics. Cleaning Procedure Close the intracavity shutter and position the appropriate power meter detector head in front ...
Related Searches: cleaning optics
|
|
|
|
|
7.
Single-Line High Reflector and Prism Cleaning
|
|
|
... edge. Never touch the optical surfaces with bare skin, the hemostats, or materials other than lens tissue. Only fresh (dry) spectroscopic grade Methanol should be used to clean optics. Cleaning Procedure Close the intracavity shutter and position an appropriate power meter detector head in front of ...
|
|
|
|
8.
pdf_129
|
Best match in this PDF
|
All matches in this PDF
|
... image and remove the photodissociation contribution. The double differential cross sections were obtained at collision energies of 8.7 kcal/mol for methanol, 6.0 and 9.7 kcal/mol for ethanol, and 11.9 kcal/mol for 2-propanol (Fig. 3). In all cases, the scattering was predominantly in the backward-sideways ...
Related Searches: fused silica | lens | radiometer | novaline
|
|
|
|
9.
THzLaserforEOWChemSatellite
(PAGE 1 OF 12)
|
|
|
... channels with a LO at 2.52 THz (these channels will be collectively referred to as the THz channel). The Local Oscillator for the THz channel is a methanol laser pumped by a CO2 laser. DeMaria ElectroOptics Systems (DEOS) leads the team that is going to deliver this laser system to JPL for integration ...
|
|
|
|
10.
THzLaserforEOWChemSatellite
(PAGE 5 OF 12)
|
|
|
... frequency reference to lock the pump laser against, a photoacoustic cell (see Figure 5) which uses the FIR Laser vibrational pump transition in methanol,2 was designed and tested. · Methanol @ ~0.5 Torr · Intra-vacuum microphone · AR windows AR Windows Pumpout Port Signal Feedthrough Figure 5: Photoacoustic ...
|
|