QI-19.138 A EPM2000 LabVIEW Building Applications Instructions Molectron Detector, Incorporated Page 8 EPM2000 Query Mode.vi Determines which mode (Statistics, Average, Normal) is currently being used by the EPM2000. EPM2000 Query Output Depth.vi Determines the depth of the…
|
|
|
|
|
3.
Cover
(PAGE 60 OF 77)
|
|
… The EPM2000 Dual-Channel Joulemeter/Power Meter is designed to provide a lifetime of simple, worry-free use. Most perceived problems are typically configuration errors. In addition to the questions and answers below, check Molectron Detector's website (http://www.molectron.com) for …
Related Searches: molectron powermax
|
|
|
|
|
6.
Microsoft Word - Epm2000LabVIEWBldgAppInst.doc
(PAGE 2 OF 12)
|
|
QI-19.138 A EPM2000 LabVIEW Building Applications Instructions Molectron Detector, Incorporated Page 2 Introduction The EPM2000 LabVIEW VI library is a collection of 57 configuration VIs that allow the construction of a wide variety of custom applications in a short time. The library…
|
|
|
|
|
7.
Microsoft Word - Epm2000LabVIEWBldgAppInst.doc
(PAGE 9 OF 12)
|
|
QI-19.138 A EPM2000 LabVIEW Building Applications Instructions Molectron Detector, Incorporated Page 9 EPM2000 Query Trigger Source.vi Determines the source of the EPM2000 channel trigger: Internal, External (positive rising edge), Slaved to the trigger bus, or External (negative…
|
|
|
|
|
8.
Cover
(PAGE 64 OF 77)
|
|
Maintenance, Service, & Calibration EPM2000/EPM2000e Reference Guide 57 INSTRUMENT CALIBRATION AND SERVICE When returned to Molectron for annual recalibration and servicing, Molectron probes and instruments include a parts and labor warranty for the life of the product. Like all test…
|
|
|
|
|
9.
Microsoft Word - Epm2000LabVIEWBldgAppInst.doc
(PAGE 11 OF 12)
|
|
QI-19.138 A EPM2000 LabVIEW Building Applications Instructions Molectron Detector, Incorporated Page 11 EPM2000 Set Statistics Send Data.vi Instructs the EPM2000 as to which data to transmit during live collection: Average, Minimum Value, Maximum Value, Standard Deviation, and/or…
|
|
|
|
|
10.
Microsoft Word - Epm2000LabVIEWBldgAppInst.doc
(PAGE 10 OF 12)
|
|
…-19.138 A EPM2000 LabVIEW Building Applications Instructions Molectron Detector, Incorporated Page 10 EPM2000 Set Datastream.vi Sets the EPM2000 output to either continuous or deactivate, according to the input choice. EPM2000 Set Mode.vi Sets the specified EPM2000 channel to…
|
|