Ask a Question
Coherent

Search Results

1 - 12 of 246 Products for 'numerical aperture' Page 1 of 21 |

numerical aperture

FAP-800-Series-Data-Sheet.pdf

FAP-800-Series-Data-Sheet.pdf

…at case temperature (TC) = 25°C. 2 Custom center wavelengths and custom spectral widths are available, some from stock. Consult your Coherent representative. 3 The numerical aperture of the output beam is defined as the sine of the half-angle of the divergence cone that encircles 90% of the energy.

FAP-600-Series-Data-Sheet.pdf

FAP-600-Series-Data-Sheet.pdf

…at case temperature (TC) = 25°C. 2 Custom center wavelengths and custom spectral widths are available, some from stock. Consult your Coherent representative. 3 The numerical aperture of the output beam is defined as the sine of the half-angle of the divergence cone that encircles 90% of the energy.

QD Fiber Optic Cable

QD Fiber Optic Cable

…available Features & Benefits Tech spec Lasers Fiber lasers, Nd:YAG, Diode lasers, Green lasers Dimensions SM-1000 µm Lengths 5-200 m Numerical aperture 0.20 Max. power (CW) 120 kW (@1030-1090nm), 10 kW (@780-1100nm) Peak power (@1064nm) 10 kW (10 ms pulse length) 50 kW (1 ms pulse length) 1…

RQB Fiber Optic Cable

RQB Fiber Optic Cable

…available Features & Benefits Tech spec Lasers Fiber lasers, Nd:YAG, Diode lasers, Green lasers Dimensions SM-1000 µm Lengths 5-200 m Numerical aperture 0.20 Max. power (CW) 1.5 kW (without external cooler) 3.0 kW (with external cooler) Peak power (@1064nm) 10 kW (10 ms pulse length) 50 kW (1…

SMAQ Fiber Optic Cable | Coherent

SMAQ Fiber Optic Cable | Coherent

…guiding (air-/water-cooled) Features & Benefits Tech spec Lasers Nd:YAG, Fiber lasers, Diode lasers Dimensions 50-300 µm Lengths 1-10 m Numerical aperture 0.20 Max. power (CW) 500 W Fiber losses < 3%, (typically 1%) Back reflections Air-cooled: 100 W for 2 s, 40 W for 60 s Water-cooled: 150 W…

Life Sciences and Medical Applications

Life Sciences and Medical Applications

…spectroscopy is a useful tool for the investigation of molecular structure, kinetics, and excited-state surfaces and dynamics. In particular, it finds numerous applications in systems of biological interest. The Innova series of frequency-doubled argon ion lasers - Innova FRED - is perfect match for…

SCSM-1060-HP1-Data-Sheet.pdf

SCSM-1060-HP1-Data-Sheet.pdf

…Diameter at 980 nm (µm) 5.4 to 6.4 Mode Field Diameter at 1060 nm (µm) 5.7 to 6.7 Mode Field Diameter at 1550 nm (µm) 9.4 to 10.5 Numerical Aperture (nominal) 0.14 Attenuation at 980 nm (dB/km) _200 Coating Material UV-cured dual acrylate TechnicalSpecifications SuperiorReliability&Performance…

SCSM-1060-HP1-Data-Sheet.pdf

SCSM-1060-HP1-Data-Sheet.pdf

…Diameter at 980 nm (µm) 5.4 to 6.4 Mode Field Diameter at 1060 nm (µm) 5.7 to 6.7 Mode Field Diameter at 1550 nm (µm) 9.4 to 10.5 Numerical Aperture (nominal) 0.14 Attenuation at 980 nm (dB/km) _200 Coating Material UV-cured dual acrylate TechnicalSpecifications SuperiorReliability&Performance…

SCSM-1060-HP1-Data-Sheet.pdf

SCSM-1060-HP1-Data-Sheet.pdf

…Diameter at 980 nm (µm) 5.4 to 6.4 Mode Field Diameter at 1060 nm (µm) 5.7 to 6.7 Mode Field Diameter at 1550 nm (µm) 9.4 to 10.5 Numerical Aperture (nominal) 0.14 Attenuation at 980 nm (dB/km) _200 Coating Material UV-cured dual acrylate TechnicalSpecifications SuperiorReliability&Performance…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…UV-VIS Minimum Power Standard UV-VIS Saturation Power Standard UV-VIS Minimum Power Incident Angle (degrees) Angular Dependence RelativeSensitivity 0.8 0 25 1.0 0.85 0.9 0.95 5 10 15 20 Numerical Aperture Numerical Aperture Dependence RelativeSensitivity 0.85 0 0.6 1.0 0.9 0.95 0.1 0.2 0.3 0.4 0.5

BIF-1310-L2-BIF-RC-1310-L2-Data-Sheet.pdf

BIF-1310-L2-BIF-RC-1310-L2-Data-Sheet.pdf

…1310 and 1550 Cut-off Wavelength (nm) <1290 Mode Field Diameter at 1310 nm (µm) 5.5 to 6.5 Mode Field Diameter at 1550 nm (µm) 6.3 to 7.5 Numerical Aperture (nominal) 0.16 Attenuation at 1310 nm (dB/km) <_0.75 Attenuation at 1550 nm (dB/km) <_0.60 Bend Loss at 1310 nm (30 turns, 10 mm radius) (dB/m)…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…UV-VIS Minimum Power Standard UV-VIS Saturation Power Standard UV-VIS Minimum Power Incident Angle (degrees) Angular Dependence RelativeSensitivity 0.8 0 25 1.0 0.85 0.9 0.95 5 10 15 20 Numerical Aperture Numerical Aperture Dependence RelativeSensitivity 0.85 0 0.6 1.0 0.9 0.95 0.1 0.2 0.3 0.4 0.5

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.