Ask a Question
Coherent

Search Results

1 - 12 of 164 Products for 'opa' Page 1 of 14 |

opa

OPerA Solo Ultrafast Optical Parametric Amplifier

OPerA Solo Ultrafast Optical Parametric Amplifier

OPerA Solo kHz OPA Fully integrated, computer-controlled femtosecond optical parametric amplifiers (OPA) extend the tuning capability of Coherent’s kHz ultrafast amplifiers from 190 nm to 20,000 nm. Contact Us About This Product Close PRICE HERE Ultrafast Optical Parametric Amplifier As the first…

Opera-F and Opera-HP

Opera-F and Opera-HP

…demanding experiments. Opera-HP The Opera-HP is an optical parametric amplifier (OPA) used to extend the performance of Coherent’s Monaco amplifier. Opera-HP is a white light seeded two stage collinear OPA, delivering 6W signal + idler at the peak. The high power, high repetition rate capabilities…

The Monaco diode-pumped femtosecond industrial laser

The Monaco diode-pumped femtosecond industrial laser

…Datasheet Monaco 517 Datasheet Monaco SmartCleave Applications Application Process Material Complex Layer Processing Glass Cutting & Drilling OPA Pumping fs Micromachining Precise Metal Marking & Cutting Thin-film Ablation Wafer Scribing Display Cutting Drilling Scribing Marking Surface Modification…

OPA 9800/9850

OPA 9800/9850

…repetition-rate
* Multiple output beams
* Frequency-doubling option Datasheet OPA 9400/9800 Drawing OPA 9800/9850 Optical Parametric Amplifiers for RegA 9000/9050 Regenerative Amplifier Accessory - The OPA 9800 and OPA 9850 are similar to the 9400 versions, using the pump beam to generate a white…

OPA 9400/9450

OPA 9400/9450

…Variable repetition rate
* Multiple output beams
* Frequency-doubling option Datasheet OPA 9400/9800 Drawing OPA 9400/9450 Optical Parametric Amplifiers for RegA 9000/9050 Regenerative Amplifier Accessory - The OPA 9400/9450 are highly efficient and easy-to-use passive devices. Pulses from the RegA…

Ultrafast Amplifiers

Ultrafast Amplifiers

…throughput requirements in the materials processing and microelectronics space. OPerA Solo kHz OPA OPerA Solo kHz OPA Opera Solo is an integrated one-box optical parametric amplifier (OPA). Used to extend the wavelength range of Astrella, Legend, and Libra amplifiers. All wavelength extensions…

Mantis DS

Mantis DS

…extend tuning to the mid-IR region Superior Reliability & Performance Mechanical Specifications OPA 9400/9450 Physical dimensions of Laser Head (L x W x H) 720 X 408 x 195 mm (28.8 x 16.3 x 7.8 in.) OPA 9800/9850 Physical dimensions of Laser Head (L x W x H) 720 X 408 x 195 mm (28.8 x 16.3 x 7.8…

1 kHz, 5 kHz and 10 kHz Ultrafast Amplifiers

1 kHz, 5 kHz and 10 kHz Ultrafast Amplifiers

…(Revolution) and the Vitara oscillator. Both the Legend family and the Libra can be combined with the OPerA Solo or TOPAS, computer-controlled OPAs providing wide tunability. Astrella is the first ultrafast Ti:Sa amplifier to be designed and produces within the Industrial Revolution in Ultrafast…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…as well as residual beams from the whitelight continuum and RegA pump beams. OPA 9400/9450 and 9800/9850 Optical Parametric Amplifiers for RegA 9000/9050 Regenerative Amplifier Accessory OPA 9400 OPA 9450 OPA 9800 OPA 9850 Repetition-Rate(kHz) 250 Pulseenergy(nJ) 80 160 AveragePower(mW) 20 40…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…& Performance 77 The DFG 9800/9850 are wavelength extension accessories for the OPA 9800 and OPA 9850 Optical Parametric Amplifiers. Both the 9800 DFG and the 9850 DFG extend the tuning of Coherent OPAs into the mid-infrared range from 2.55 µm to >10 µm. This level of operation makes the…

2016-Ultrafast-Laser-Systems-Catalog.pdf

2016-Ultrafast-Laser-Systems-Catalog.pdf

…· www.Coherent.com · tech.sales@coherent.com66 The OPerA Solo is a fully integrated, computer-controlled femtosecond optical parametric amplifier (OPA) that extends the wavelength accessibility of the Astrella, Legend Elite and Libra amplifiers from 190 nm to 20 µm. As the first unit of its kind,…

DFG9800 DSrevA 3.qxd

DFG9800 DSrevA 3.qxd

…Parametric Amplifiers--the OPA 9800 and OPA 9850. Both DFG units extend the tuning of Coherent's OPAs into the mid-IR range. When combined as part of a Coherent all-solid-state ultrafast system, consisting of the VerdiTM, MiraTM 900, RegATM 9000, and OPA 9800 or OPA 9850, the DFG 9800/9850 allows…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions