UNITED STATES SECURITIES AND EXCHANGE COMMISSION Washington, D.C. 20549 FORM 10-K (Mark one) [X] ANNUAL REPORT PURSUANT TO SECTION 13 OR 15(d) OF THE SECURITIES EXCHANGE ACT OF 1934 For the Fiscal Year Ended September 28, 2002 OR [ ] TRANSITION REPORT PURSUANT TO SECTION 13 OR 15(d) OF THE SECURITIES ... Related Searches:tutcore | lpx pro 220 | co2 laser price | compex 102
... of the result. In the following paragraphs the performance parameters of the high repetition rate - medium energy, solid state pulsed excimer laser OPTexPro is discussed. 2.1 Output Performance Energy Stability Employing proven NovaTube® metal-ceramic technology as well as optimized gas flow dynamics ... Related Searches:excimer lamp | excimer
... of the result. In the following paragraphs the performance parameters of the high repetition rate - medium energy, solid state pulsed excimer laser OPTexPro is discussed. 2.1 Output Performance Energy Stability Employing proven NovaTube® metal-ceramic technology as well as optimized gas flow dynamics ...
Figure 9: Bar code on paper obtained by color change from a single-pulse exposure using OPTexPro at a wavelength of 308 nm. The energy density applied on the paper surface was 600 mJ/cm2; Courtesy of Fraunhofer IWS, Dresden, Germany In dermatology OPTExPro provides 308 nm output at an energy level ...
Annual Report, Proxy Statement & Notice of Annual Meeting 2004 In the highly sophisticated industry of photonics, Coherent, Inc. leads the way, offering reliability, cost and performance advantages for the widest range of commercial and scientific research applications. Founded in 1966, Coherent ... Related Searches:890 | ops laser | field master | hair removal
SoundStrategiesforSuccess 2005AnnualReport,ProxyStatement andNoticeofAnnualMeeting In the highly sophisticated industry of photonics, Coherent, Inc. leads the way, offering reliability, cost, and performance advantages for the widest range of commercial and scientific research applications. Founded ... Related Searches:lumenis | enterprise | model 212 power meter | 210 power meter
2.2 Laser Beam Parameters Beam Profile Measured at 30 cm from the beam exit (near field) the OPTexPro exhibits the rectangular near-field beam intensity distribution which is typical for excimer lasers. Along the vertically aligned long axis a top-hat profile is obtained, whereas along the horizontally ... Related Searches:fast photodiode
... particular from duty-cycle variations, the laser tube temperature is regulated to ± 1°C by a feedback mechanism. Figure 2: Energy stability of the OPTexPro at 193 nm and 500 Hz repetition rate over the relative high voltage setting range. Each data point corresponds to a measurement over 1000 laser ...
The 500 Hz solid state switched OPTexPro series is tailored to meet today's needs of low-duty cycle markets dominated from an economic viewpoint by the demands of very low investment costs in conjunction with high process flexibility. These fields of applications comprise medical excimer laser markets ...
... cable and electronic components marking to name but a few. Figure 8: Bar code on paper obtained by color change from a single-pulse exposure using OPTexPro at a wavelength of 308 nm. The energy density applied on the paper surface was 600 mJ/cm2; Courtesy of Fraunhofer IWS, Dresden, Germany Since the ...