Search for Lasers, Laser Systems, Laser Measurment, Laser Service Coherent Inc., Worldwide websites Coherent Inc., calendar of events Coherent Inc., office locator Coherent Inc., Service Centers
     > Search
Search Coherent
Coherent Inc.
Superior Reliability & Performance
  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
Please enter a search phrase.

1 - 10 of 24 Search Results for piezoelectric
Search Suggestions: jmax43 | wire grid polarizer | j25lp-1 | wire grid | dpy | jd501 | om4001 | digitizer | j3-09 | laser pdf

1pdf document  ACF2A09 Best match in this PDF  |  All matches in this PDF
... , the unique crystalline pyroelectric material boasts a lower capacitance, allowing rep rates as high as 20,000 pps (in the HR models) and lower piezoelectric coefficient minimizing microphonic noise. The J25 (25 mm diameter) and J50 (50 mm) probes provide a nearly flat spectral response from UV to Far ...
Related Searches: j25lp-1 | wire grid | jd501 | digitizer

2pdf document  BBO_DS  (PAGE 2 OF 2)
... Coefficients ( 10-6/°K ) 11 = 4; 33 = 36 Dielectric Constants 11 = 6.7; 33 = 8.1 Loss Tangent <0.001 Resistivity (x106 m) 11 = 10.15; 33 = 16.31 Piezoelectric Constants (x10-3 V/m/N) g33 = 55.12; g31 = -11.73; g15 = 23.30; g16 = 5.20 Pyroelectric Coefficient (µC / m2 . °K ) 33 = 14.5 Optical Homogeneity ...

3pdf document  NASA-GoddardRev2 Best match in this PDF  |  All matches in this PDF
To be published in The Proceedings of the Eleventh International Symposium on Space Terahertz Technology, Ann Arbor, MI (2000) Stabilized, Integrated, Far-Infrared Laser System for NASA/Goddard Space Flight Center Eric R. Mueller, Joel Fontanella, and Robert Henschke DeMaria ElectroOptics Systems, ...
Related Searches: thz laser | laser in use sign

4pdf document  LBO_DS  (PAGE 2 OF 2)
... = 66; y = 20 ; z = -53 Dielectric Constants (@ 100kHz , 25°C) x = 7.5; y = 5.9; z = 9.8 Loss Tangent x = 1.3 x 10-3; y = 1.2 x 10-4; z = 2.3 x 10-2 Piezoelectric Constants (x 10-12 C/N) d33 = 9.4; d31 = 4.2; d15 = 1.4; d32 = 1.9; d24 = 1.0 Optical Homogeneity (cm-1) n < 10-6 Transparency Range (nm ...

5pdf document  NASA-GoddardRev2  (PAGE 3 OF 8)
... is then mixed with an offset synthesizer. The resulting IF is processed through a delay discriminator to generate an error signal for the pump laser piezoelectric transducer (PZT) control. The sign of the offset (ie. below or above CO2 line center) is set with a simple sign flip in the error loop circuitry ...

6Laser Spectrum Analyzer System
... a scanning Fabry-Perot interferometer cavity with two concave mirrors. The separation distance between the mirrors is varied slightly using a piezoelectric section of a mirror spacer. A ramp-scan voltage supplied from the Spectrum Analyzer controller drives the piezoelectric. The variation in the mirror ...
Related Searches: fabry | fabry perot cavity | spectrum | fabry perot

7pdf document  ss259 Best match in this PDF  |  All matches in this PDF
MANAGEMENT REGULATIONS FOR THE ENVIRONMENT-RELATED SUBSTANCES TO BE CONTROLLED WHICH ARE INCLUDED IN PARTS AND MATERIALS The 3 rd edition of SS-00259 (excerpts) Copyright 2004 Sony Corp. ALL RIGHTS RESERVED No part of this document may be reproduced or transmitted in any form or by any means, electronic ...
Related Searches: semiconductor

8pdf document  10A-BeamDiagnosticsSpectralAnalysisRev1 Best match in this PDF  |  All matches in this PDF
Product Name Index Part Number Index Laser CrossReference Index INDICES Spectral Analysis Beam Diagnostics BEAM DIAGNOSTICS & SPECTRAL ANALYSIS Calibration & Service Custom & OEM Power & Energy Accessories Energy Sensors Power Sensors POWER & ENERGY Power & Energy Meters Coherent ...
Related Searches: 33-6164-000 | 205 power meter head | 33-6289-001 | fabry

9pdf document  10A-BeamDiagnosticsSpectralAnalysisRev1  (PAGE 5 OF 8)
... a scanning Fabry-Perot interferometer cavity with two concave mirrors. The separation distance between the mirrors is varied slightly using a piezoelectric section of a mirror spacer. A ramp-scan voltage supplied from the Spectrum Analyzer controller drives the piezoelectric. The variation in the mirror ...
Related Searches: fabry perot cavity | fabry perot

10pdf document  10A-BeamDiagnosticsSpectralAnalysisRev1  (PAGE 6 OF 8)
... Range (FSR) of a Spectrum Analyzer is the maximum optical spectral span created by the variation of the separation of the two mirrors while the piezoelectric spacer is repeatedly ramped. It is dependent on the mirror mean separation: d, as FSR = C/4d in frequency units. In Spectrum Analyzers from Coherent ...


Search Suggestions: jmax43 | wire grid polarizer | j25lp-1 | wire grid | dpy | jd501 | om4001 | digitizer | j3-09 | laser pdf
Page 1 2 3 of 3 | Next


Site Search by  Site Search powered by SLI Systems