1pdf document  Epm2000RG Best match in this PDF  |  All matches in this PDF
…/pyroelectric joulemeter probes, responsivity must be programmed manually. Follow all laser safety procedures. Laser must be blocked or switched off before beginning this procedure. Do not exceed the power/energy density limits for the pyroelectric probe as defined in the probe's data sheet. 1. Place the…
Related Searches: declaration of conformity | epm2000 manual | pyroelectric detector | molectron power meter

2pdf document  EPM1kUG Best match in this PDF  |  All matches in this PDF
…on the probe type) · Power 1 mW to 10 kW in 15 ranges · Frequency 0.1 Hz to 500 Hz · Volts 2 mV to 30 V (for pyroelectric/silicon probes) · Volts 200 µV to 1 V (for thermopile probes) For more details, see Specifications. Features & Description EPM1000 User's Guide8 Compatible Probes The EPM1000…
Related Searches: auto correlator | epm1000 | molectron j25 | communication interface

3Coherent Inc. How to Use a Pyroelectric Joulemeter Probe with a Standard Oscilloscope
…joulemeter probe into an oscilloscope to read a peak voltage (energy) sounds very simple, it can be a challenge the first time. This Application Note is written to give you a few tips and a head start on the learning curve. The first section of this is on selecting the right joulemeter probe -- we will…
Related Searches: molectron j3 | j3 | j50 | j25

4pdf document  pdf 232 Best match in this PDF  |  All matches in this PDF
…Pump-probe-experiments are quite common using two laser pulses. They significantly increase the selectivity and sensitivity of experiments in fundamental and applied research. For example, one photon excites the system selectively into a specific state, so that another, time correlated photon probes its…
Related Searches: excimer pumped dye laser | ns laser | krf laser | lambda physik dye laser

5pdf document  HighLight 4000L Preinstallation Manual Best match in this PDF  |  All matches in this PDF
…(detector head plus display console) is necessary. Water cooling is generally required for the detector head at the HighLight 4000L power levels. Make sure to provide adequate cooling for the detector head. Coherent manufactures a wide range of power meters (display consoles and sensor heads). Refer to…
Related Searches: laser wire stripper | evolution manual | water wheel | manual

6pdf document  PM-Digital Best match in this PDF  |  All matches in this PDF
…Then MsgBox "No Probe" If (lngStatus And &H4) = &H4 Then MsgBox "Over Temp" If (lngStatus And &H8) = &H8 Then MsgBox "Bad Ref" If (lngStatus And &H10) = &H10 Then MsgBox "Bad CSum" If (lngStatus And &H20) = &H20 Then MsgBox "Bad Zero" If (lngStatus And &H40) = &H40 Then MsgBox "Bad Head" End Sub Host Interface…
Related Searches: pm-digital | pm-digital driver | calorimeter | pm-5200

7pdf document  3sigmaLVDriverUG Best match in this PDF  |  All matches in this PDF
…error) Default: False, 0, "" Outputs: dup VISA session Probe Information [Calibration Date , Model , Responsivity , Serial Number , Head Temperature , Type {"NONE", "THERMO", "PYRO", "SILICON"}…
Related Searches: labview drivers | manual 3sigma | molectron

8Coherent Inc. Absolute Calibration of Kilowatt Laser Thermopile Power Meters
…The disk-shaped laser absorber/water cooling assembly was removed from the metal housing of a PM3K probe. The absorber assembly along with immersion type high precision Pt resistance temperature probes on the cooling water inlet and outlet were encased in urethane foam insulation. The foam obviously…
Related Searches: calorimeter | thermopile

9Coherent Inc. CO2 No Laser Output Beam – DIAMOND Basic/PP
…If power meter/probe is available measure the output power at this setting. Consult the operator´s manual for typical output power at this setting for your laser model. Verify that the laser tube is actually receiving modulation by monitoring the sound coming from the laser head. * If RF warning…

10Microsoft Word - 3sigma LabVIEW Driver User Guide.doc  (PAGE 30 OF 41)
…cluster>
Default: False, 0, ""
Outputs: dup VISA session
Probe Information [Calibration Date , Model ,
Responsivity , Serial Number , Head
Temperature , Type {"NONE",
"THERMO", "PYRO…


Page 1 2 3 4 of 4 | Next