Search
Superior Reliability & Performance

  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
1 - 10 of 110 Search Results for pulse check

1pdf document  Avia 355-355X Preinstallation Best match in this PDF  |  All matches in this PDF
pulse (See Section Three, Operation, within the operator's manual for details). Note that this is an alternate to DB 25 pins 20 and 21 Pulse Sync Out TTL low output signal synchronous with the laser pulses. External Enable Active low TTL input. If the signal is disconnected or pulled high no laser pulsing
Related Searches: coherent avia-355 laser | pulse check | manual | avia-x

2pdf document  EnergyMaxGuide revA 10 FINAL Best match in this PDF  |  All matches in this PDF
…EnergyMaxSensors Device Specifications Features · Pulse enegy measurement down to 20 pJ and up to 6 µJ (within line; model dependent) · Average power measurement of pulsed sources from nW to mW level signal-to-noise characteristics · Measures single pulses to 10,000 Hz · Accurate spectral compensation…
Related Searches: energy max | j-25mb | j-10si | j-50mt

3pdf document  LMC 2011catalog 0411 Best match in this PDF  |  All matches in this PDF
…Long-Pulse Energy Measurement with a Thermopile Power Sensors Introduction Thermopile sensors are most commonly used for average power measurements on pulsed and CW lasers.Thermopiles are also capable of integrating long pulse widths.This allows the thermopile to measure the energy of single pulses between…
Related Searches: optics catalog | thermopile response wavelength | 4 quadrants | manual lm-10 htd

4pdf document  Epm2000RG Best match in this PDF  |  All matches in this PDF
…been set to 8% (dashed line). Pulse D will definitely not generate a reliable trigger. Pulse C may generate a trigger, but not reliably. Pulses A and B will definitely generate reliable triggers. Features & Description EPM2000/EPM2000e Reference Guide 5 Figure 1: Pulses which will or will not trigger…
Related Searches: declaration of conformity | 60 watt | molectron epm2000 | power meter probe

5pdf document  EnergyMaxSensors UserManual RevAB Best match in this PDF  |  All matches in this PDF
Pulse Energy The following procedure explains how to measure laser pulse energy. 1. Test the sensor coating to determine its laser damage tolerance: Before placing the sensor in the beam path, position the damage test slide--which has the same coating as the sensor--in the beam path for a few pulses
Related Searches: field max ii top power energy meter | field max ii top | db25 | db-25 smart

6pdf document  COHR LMC 2010-2011catalog Best match in this PDF  |  All matches in this PDF
…Tel: (408) 764-4042 · Fax: (503) 454-5727 Features · Pulse enegy measurement down to 8 pJ (within line; model dependent) · Average power measurement of pulsed sources from nW to mW level signal-to-noise characteristics · Measures single pulses to 10,000 Hz · Accurate spectral compensation - 325 nm…
Related Searches: power meter model 201 | volume absorber | lm-10 price | broadband laser

7pdf document  Avia 266 Preinstallation Best match in this PDF  |  All matches in this PDF
pulse (See Section Three, Operation, within the operator's manual for details). Note that this is an alternate to DB 25 pins 20 and 21 Pulse Sync Out TTL low output signal synchronous with the laser pulses. External Enable Active low TTL input. If the signal is disconnected or pulled high no laser pulsing
Related Searches: short pulse laser | power supply | beam shutter | shutter kits

8pdf document  EPM1kUG Best match in this PDF  |  All matches in this PDF
…. Pulse A will definitely not generate a reliable trigger. Pulse B may generate a trigger, but not reliably. Pulses C and D will definitely generate reliable triggers. 5% 10% 15% Trigger Level A DCB Definitely will not trigger May trigger, but not reliable Definitely will trigger Figure 1: Pulses which…
Related Searches: auto correlator | molectron epm1000 | epm1000 | thermopile response wavelength

9pdf document  HighLight 4000L Preinstallation Manual Best match in this PDF  |  All matches in this PDF
…signals are referenced to the common provided at terminal 2081. External Pulse Input This terminal is used to provide an external pulse input for controlling the laser pulsing operation. This signal should be limited to TTL levels. Pulses provided on this connection should be within the stated operating parameters…
Related Searches: class 1 | laser direct synthesis | halogen filter set | coherent logo

10pdf document  UCLD Catalog Customer 4-12 Best match in this PDF  |  All matches in this PDF
Coherent Laser Training Catalog Customer Training Program Description of Courses L aser Training Progra m CO2 ·CW · DPSS · Excimer · Ion · Pulsed · Ultrafast Established 1966 He adquarters - Santa Clara, California U.S. A. Coherent Training Catalog - Description of Courses ii This document is…
Related Searches: coherent silhouette ii | halogen filter | optical coherence | ls670


Page 1 2 3 4 5 6 7 8 9 10 11>> of 11 | Next


Site Search by  Site Search powered by SLI Systems
.