... -designed MRU air recirculator, Chameleon tunes effortlessly through atmospheric water vapor absorption lines, without the need for an external purge. Dependable as well as agile, Chameleon incorporates our patented, field-proven Kerrlens modelocking technique, which is the most straightforward, reliable ... Related Searches:chameleon | chameleon laser | coherent chameleon
... , the pass-through should be baffled or hooded to prevent stray light from exiting any laser safety enclosure. The process head accessories (chiller, purge gas supply and any controls) must be sited such that the length of tubing and cabling can reach the process head under all operating conditions. ...
... stability, or frequency stability, the use of pressure and temperature regulators on the cooling water system may also be advantageous. Nitrogen Purge A steady flow of 0.5-1.0 SCFH (Standard Cubic Feet/Hour) of dry Nitrogen is required in order to keep proper intracavity space conditions. The Nitrogen ... Related Searches:bbo crystal
... , the laser tube windows achieve typical lifetimes of 100 to 200 million pulses depending on the operational duty cycle, and the externally mounted, purged resonator optics in the LPX typically last more than 200 million laser pulses. The performance of an excimer laser is dependent on laser gas, the ... Related Searches:pointing stability | lpx | halogen filter
... a moving average window of 100 laser pulses. 2.2 Optical Stability Operation at 193nm wavelength requires careful selection of materials and perfect purging of the beam path. At a laser power level significant amount of energy is deposited in the optical elements and modules due to absorption losses ...
... the accessory manuals for physical specifications (size and weight) as well as all additional space recommended for service access and ventilation. Purge Gas To maintain non-condensing operation of the HighLight 1000F it is important to provide the proper purge gas supply as specified below and in Table ...
... /gal) or 100 parts/million of calcium Particulate size <200 microns in diameter. 5 Maximum heat load 20 kW @ 230 VAC 18 kW @ 208 VAC NITROGEN PURGE Recommended flow rate 0.5 to 1.0 SCFH Note: These figures include the two 7.6 meter (25 ft.) lengths of 16 mm (5/8 inch) I.D. hose which are supplied ...
HighLight 1000F OEM Pre-installation Manual 4 Coherent strongly recommends running the purge gas continuously (24/7) in very humid environments, whether the laser is in use or not; an oil-free air compressor, dryer, and filter may be economical in some situations. High-pressure bottles (Praxair, Linde ...