100_E-400_Series_Preinstall.book  (PAGE 21 OF 55)
Filtered to remove particles larger than 1 micron.
2. Dried so that dew point is 10°C (18°F) lower than the inlet
cooling fluid temperature to the E-400 Series laser.
3. Oil free to better than 99.995%.
Recommended purge gas configurations are shown in Figure 4.
Figure 4. Purge

2pdf document  Diamond Integrators Guide RevAA Best match in this PDF  |  All matches in this PDF
…environments is to have the beam path from the laser to the final focusing lens completely sealed, and purged with clean gas. Purge Gas Diamond K-series lasers have a purge gas inlet. The recommended gas is dry nitrogen, which is most conveniently obtained from a Dewar (nitrogen from cylinders, in addition…
Related Searches: recirculator | oem controller | oem manual | diamond manual

3pdf document  OmniBEAM Preinstallation Manual Best match in this PDF  |  All matches in this PDF
…specific advice for your location.. (Cutting) Assist Gas System The LMC requires dry, filtered air or other gas to protect the cutting lens and assist in the cutting process. The assist gas connection to the LMC is a ¼" flexible tube. The gas supply must be regulated between 50 and 150 psi. If the…
Related Searches: metabeam | lmc catalog | wiring diagrams | omnibeam

4pdf document  LightCELL Preinstallation Manual Best match in this PDF  |  All matches in this PDF
…specific advice for your location.. (Cutting) Assist Gas System The LMC requires dry, filtered air or other gas to protect the cutting lens and assist in the cutting process. The assist gas connection to the LMC is a ¼" flexible tube. The gas supply must be regulated between 50 and 150 psi. If the…
Related Searches: laser chiller | laserlink

500_HighLight_4000_Pre.book  (PAGE 48 OF 83)
…extremely high-purity air as purge
gas, it also may use economical medical or breathing-grade air,
available in standard cylinders or from air treatment systems.
The HighLight 4000L requires clean, dry, oil-free air (filtered to
0.01 µm) for purge gas, with the following specifications…
Related Searches: highlight 4000l

6pdf document  HighLight 4000L Preinstallation Manual Best match in this PDF  |  All matches in this PDF
…meet the laser purge gas specifications, a Kaeser Filter/Dryer panel may be installed. Refer to Table 13 for the description of the call-outs in Figure 31. Shop Air must meet the specifications below to use the Kaeser Filter/Dryer panel: · Dew point to 37.8°C (100°F) or less · Filtered to 5 µm particle…
Related Searches: class 1 | laser direct synthesis | halogen filter set | coherent logo

700_Diamond_Int.book  (PAGE 31 OF 55)
…is to have the beam path from the laser to
the final focusing lens completely sealed, and purged with clean gas.
Purge Gas Diamond K-series lasers have a purge gas inlet. The recommended
gas is dry nitrogen, which is most conveniently obtained from a
Dewar (nitrogen from cylinders…

8pdf document  Diamond E-400 Series Preinstallation Manual Best match in this PDF  |  All matches in this PDF
Purge Gas [ ] N2 or filters installed to provide clean, dry air [ ] Shut-off valve installed (optional, recommended) [ ] Output fitting installed to accept 1/4" OD tubing [ ] Clean, flexible 1/4" OD tubing to connect purge gas supply to laser head "Laser System Purge Gas" on page 11 "Purge Gas Filter
Related Searches: rf module | p n | java applet | java

9pdf document  DIAMOND E1000 premanual Best match in this PDF  |  All matches in this PDF
Purge Gas [ ] N2 or filters installed to provide clean, dry air [ ] Shut-off valve installed (optional, recommended) [ ] Output fitting installed to accept 1/4" OD tubing [ ] Clean, flexible 1/4" OD tubing to connect purge gas supply to laser head "Laser System Purge Gas" on page 14 "Purge Gas Filter
Related Searches: shutter kits | laser beam diagnostics | dc power supply | diamond 84

10pdf document  Innova300C fredmotofred preinstallation Best match in this PDF  |  All matches in this PDF
…contaminated gas should not be used with the Innova 300C FreD / MotoFreD ion laser. If bottled compressed gas is used, specify a purity of grade 5 (99.999%) or better. A high purity "boil off" nitrogen source may be used as an alternative. Make sure that all regulators and lines are clean and the filter is installed…
Related Searches: innova 300c fred | innova 90 user manual | fieldmaster power meter | innova 300c


Page 1 2 3 4 5 6 7 8 of 8 | Next


Site Search by  Site Search powered by SLI Systems
.