1 - 10 of 146 Search Results for response time
|
|
|
1.
Absolute Calibration of Kilowatt Laser Thermopile Power Meters
|
|
... ’s tool. Coherent lasers & laser measurement Metrology Joulemeters Probes Oscilloscopes A Coherent Application Note Jesse D. Buck, Ph.D. At the time of the measurements described below (1993), kilowatt level CW laser calibrations were not available from N.I.S.T. To achieve accurate calibrations ...
Related Searches: optical power meter
|
|
|
|
4.
co2_LFW_opticalnoseRev2
|
Best match in this PDF
|
All matches in this PDF
|
... . Consequently, the ability to rapidly, accurately, and noninvasively determine the level of these gases in a patient's breath in situ and in real time can have a profound impact on diagnosis, treatment, and end results. For example, during dialysis, monitoring the level of ammonia in the breath of a ...
Related Searches: bloomfield ct
|
|
|
|
5.
co2_LFW_opticalnoseRev2
(PAGE 2 OF 4)
|
|
|
... . Consequently, the ability to rapidly, accurately, and noninvasively determine the level of these gases in a patient's breath in situ and in real time can have a profound impact on diagnosis, treatment, and end results. For example, during dialysis, monitoring the level of ammonia in the breath of a ...
|
|
|
|
6.
Epm2000RG
(PAGE 15 OF 78)
|
|
|
... to determine laser power quickly and accurately. However, some probes, such as the PM5K, which can measure power as high as 7500 Watts, have a long response time. The EPM2000 solves this problem by using probe information and an internal algorithm, called the Speedup feature, to quickly estimate the ...
|
|
|
|
7.
EPM1kUG
(PAGE 15 OF 60)
|
|
|
... to determine laser power quickly and accurately. However, some probes, such as the PM5K, which can measure power as high as 7500 Watts, have a long response time. The EPM1000 solves this problem by using probe information and an internal algorithm, called the Speedup feature, to quickly estimate the ...
|
|
|
|
9.
LaserGageUM
(PAGE 22 OF 26)
|
|
|
... parts. LG100 LG500 Power Range (W) 10 to 100 50 to 500 Power Resolution (W) 0.1 0.1 Accuracy (+/- %) (NIST-traceable) 5 5 Repeatability (+/- %) 3 3 Response Time (sec) 4 4 Damage Threshold, Absorber (kW/cm2) @10.6 µm 1 0 4 Overtemperature Alarm Setting (deg. C) 150 150 Auto Power Timeout (sec) 3 0 3 ...
|
|
|
|
10.
PM500A
(PAGE 8 OF 12)
|
|
|
5 Maintenance Display Speedup Selection Jumper Display Speedup The PM500A features an electronic circuit to speed up response time. The circuit is factory enabled by a jumper across test points 4 and 5. To disable the speed up circuit: 1 . First contact the factory to prevent voiding the warranty by ...
|
|