1Coherent Inc. CO2 RF Warning Faults – DIAMOND OEM Laser
…Connector Connected to RF Amp Related symptoms; See chapter titled "Maintenance and Troubleshooting" in the Operator's Manual for definition of RF warnings. (note: Warning faults can come on without problems in transient conditions.) See Operator's Manual illustration titled, RF Amplifier Output Singals…
Related Searches: rf amplifier | rf co2 lasers | operation manual

2Coherent Inc. CO2 RF Warning Lights On
…operation. If VSWR is still illuminated try replacing the RF cable (system off, facility power disabled), if fault doesn't clear see step 5. * 3rd Check - Forward warning indicator on. The most likely cause for this warning indicator is the RF amp. If the Reflected fault light is on, set system to ~ 10%…

3pdf document  DIAMOND E1000 premanual Best match in this PDF  |  All matches in this PDF
…Skipping down to the action. 065|000|000|255|011|021|002|048 066|000|000|255|011|021|002|048 067|000|000|255|009|021|002|048 -RF now fired up, must be low duty since only 2 amps sso 1 068|000|000|255|018|021|003|048 165521208004 -15:37:10, FPGA reports shutter open 069|000|000|255|010|021|002|048 070|000…
Related Searches: shutter kits | laser beam diagnostics | dc power supply | diamond 84

4pdf document  Diamond Integrators Guide RevAA Best match in this PDF  |  All matches in this PDF
RF cable, or both. 6 VSWR Fault Open collector output Will sink 25 mA of current when an VSWR fault occurs. This indicates an excessive mismatch between the laser head and the RF power supply. 7 - Not currently used. 8 VDC Voltage output signal +15 VDC ± 0.5 VDC, 0.25 amp max output available from RF
Related Searches: recirculator | oem controller | oem manual | diamond manual

5pdf document  EOSChem1SatelliteRev2 Best match in this PDF  |  All matches in this PDF
…high-reliability FIR lasers may not be familiar. Starting with the pump laser technology: the LLO will utilize the same high-reliability, sealed-off, RF-excited, CO2 laser technology found in DEOS's commercial lasers and in numerous highsophistication systems DEOS has delivered over the years. Specifically…
Related Searches: methanol | photoacoustic | laser application in engineering field | telescope

6pdf document  THzLaserForEOWChemSatelliteRev2 Best match in this PDF  |  All matches in this PDF
…high-reliability FIR lasers may not be familiar. Starting with the pump laser technology: the LLO will utilize the same high-reliability, sealed-off, RF-excited, CO2 laser technology found in DEOS's commercial lasers and in numerous highsophistication systems DEOS has delivered over the years. Specifically…
Related Searches: rf-excited co2 laser | terahertz | methanol | rf power supply

7Coherent Inc. CO2 No Laser Output Beam – DIAMOND OEM
…On, troubleshoot as necessary. * Verify that RF cable connections at the laser head and the RF amp, are okay, not burnt verify that the RF cable is not damaged. Replace cable if necessary. * If DC voltage is okay. Disconnect 25 pin connector from RF amp. Click here for illustration. Using Oscilloscope…

8Coherent Inc. CO2 Laser System Doesn’t Turn On – OEM Version
…power supply from the RF amp. Verify that 48 V is at the output of the DC power supply while disconnected. If not replace the DC. * Reconnect the RF amp to the DC power supply. Verify that 48 V is at the input of the RF amp. Click here for illustration. If not replace the RF amp. * Turn off the 48 V supply…
Related Searches: rf power supply

9pdf document  Avia 266 Preinstallation Best match in this PDF  |  All matches in this PDF
…Preinstallation Manual 6 Table 1. Utility Requirements PARAMETER REQUIREMENT AC Voltage Requirements 100 to 240 VAC[1] , 47-63 Hz Maximum Current 10 Amps @ 115 VAC 5 Amps @ 230 VAC Cooling: Laser head: Power supply: Conductive to baseplate Air cooled with ambient air Note: All specifications and requirements are…
Related Searches: short pulse laser | power supply | beam shutter | shutter kits

10pdf document  Avia 355-355X Preinstallation Best match in this PDF  |  All matches in this PDF
…operator's manual. 5 Table 1. Utility Requirements PARAMETER REQUIREMENT AC Voltage Requirements 100 to 240 VAC[1] , 47-63 Hz Maximum Current 10 Amps @ 115 VAC 5 Amps @ 230 VAC Cooling: Laser head: Power supply: Conductive to baseplate Air cooled with ambient air Note: All specifications and requirements are…
Related Searches: coherent avia-355 laser | pulse check | manual | avia-x