Search for Lasers, Laser Systems, Laser Measurment, Laser Service Coherent Inc., Worldwide websites Coherent Inc., calendar of events Coherent Inc., office locator Coherent Inc., Service Centers
     > Search
Search Coherent
Coherent Inc.
Superior Reliability & Performance
  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
Please enter a search phrase.

1 - 10 of 161 Search Results for rise time
Search Suggestions: joulemeter | diamond | pulse width measurement | pyroelectric detector | epm2000 | declaration of conformity | molectron power meter | thermopile basics | molectron | peak power

1pdf document  giseries100iDS Best match in this PDF  |  All matches in this PDF
... high. The mode quality of the G-100i is excellent, with an M2 of less than 1.3. Coupled with this excellent mode quality is the G-100i's fast pulse rise and fall time--less than 80 µs. The faster the optical rise time, the lower the heataffected-zone (HAZ). The remaining characteristic is peak power ...
Related Searches: diamond | peak power | rf

2pdf document  Epm2000RG Best match in this PDF  |  All matches in this PDF
... searches for peaks and from the trigger point back, it searches for a baseline. The EPM2000 can be programmed to ignore triggers for a specified time after a valid trigger. This prevents "false" triggers in pulse tails from accidentally starting a new sample (see Figure 2). This amount of ...
Related Searches: pulse width measurement | pyroelectric detector | epm2000 | declaration of conformity

3pdf document  2002_AnalChem_VUV-lamp-TOFMS_2 Best match in this PDF  |  All matches in this PDF
Single Photon Ionization (SPI) via Incoherent VUV-Excimer Light: Robust and Compact Time-of-Flight Mass Spectrometer for On-Line, Real-Time Process Gas Analysis F. Mu1hlberger, J. Wieser, A. Ulrich,§ and R. Zimmermann,,|* GSF-Forschungszentrum GmbH, Institut fu¨r O¨ kologische Chemie, D-85764 Oberschleissheim ...
Related Searches: excimer lamp | excimer | beam view analyzer

4pdf document  PLDWhitepaperfinal050505Rev2  (PAGE 1 OF 7)
... preionization. (Fig.5). Short Pulse Width In order to rapidly reach the ablation threshold, the optimum laser pulse shape for PLD must have a fast rise time. This fast rise time must be followed by a pulse that is short enough to cause all material removal to occur by direct evaporation, rather than ...

5pdf document  BioinstrumentationOverview2008View  (PAGE 22 OF 36)
... quality)3 <1.5 Beam Asymmetry3 <1:1.2 1:3.8 Laser Drive Modes Digital, Analog & PC Control Digital Modulation Maximum Bandwidth (MHz) 125 Rise Time (10% to 90%) (nsec) <2 Fall Time (10% to 90%) (nsec) <3 Modulation Depth (extinction ratio) >1,000,000:1 at 0 Hz, >250:1 at 125 MHz ...

6pdf document  PLDWhitepaperfinal050505Rev2 Best match in this PDF  |  All matches in this PDF
... preionization. (Fig.5). Short Pulse Width In order to rapidly reach the ablation threshold, the optimum laser pulse shape for PLD must have a fast rise time. This fast rise time must be followed by a pulse that is short enough to cause all material removal to occur by direct evaporation, rather than ...
Related Searches: pulsed laser deposition

7pdf document  BioinstrumentationOverview2008View  (PAGE 21 OF 36)
... :1.2 <1:1.2 Laser Drive Modes Digital, Analog Digital, Analog & PC Control & PC Control Digital Modulation Maximum Bandwidth (MHz) 150 150 Rise Time (10% to 90%) (nsec) <2 <2 Fall Time (10% to 90%) (nsec) <2 <2 Modulation Depth (extinction ratio) >1,000,000:1 at 0 Hz, >1 ...

8pdf document  BioinstrumentationOverview2008View  (PAGE 27 OF 36)
... )3 <<_1.1 Beam Asymmetry3 <<_1:1.1 Laser Drive Modes Digital, Analog & PC Control Digital Modulation Maximum Bandwidth (MHz) 150 Rise Time (10% to 90%)(nsec) <2 Fall Time (10% to 90%)(nsec) <2 Modulation Depth (extinction ratio) >1,000,000:1 at 0 Hz, >250:1 at 150 MHz Analog ...

9pdf document  DIAMOND_brochure  (PAGE 8 OF 11)
Clean, fast and efficient material removal with minimal heat-induced damage. Each pulse from a DIAMOND laser has a square-wave profile with fast rise-and-fall times. Material processing is efficient, cuts and drilled holes are clean, and the heataffected zone (HAZ) is minimal. DIAMOND lasers also feature ...

10JM-Analog
... BNC Analog Output Connector BNC Serial Communications DB-9 (binary, 9600 baud) Power Connector Positive locking type Probe Characteristics Min. rise time (10 to 90%) 3 µsec Max. rise time (10 to 90%) 500 µsec Min. fall time (100 to 37%) 450 µsec Max. fall time (100 to 37%) 50 ms Weight 0.9 lb Dimensions ...


Search Suggestions: joulemeter | diamond | pulse width measurement | pyroelectric detector | epm2000 | declaration of conformity | molectron power meter | thermopile basics | molectron | peak power
Page 1 2 3 4 5 6 7 8 9 10 11>> of 17 | Next


Site Search by  Site Search powered by SLI Systems