Search Results

25 - 36 of 76 Products for 'rms noise' Page 3 of 7 |

rms noise

COHR OBISfamily DS 0818 8.pdf

COHR OBISfamily DS 0818 8.pdf

…integrate the product of their choice much faster, thereby reducing their time-to-market and costs. OBIS LX/LS lasers deliver superior power, low RMS noise, and higher beam quality that are key customers needs from any laser source. Coherent has implemented an intelligent design that allows multiple…

COHR StingRay BioRay DS 0618 3.pdf

COHR StingRay BioRay DS 0618 3.pdf

…<1.5
Pointing Stability over Temperature (µrad/°C) <10
Beam Angle (boresight) (mrad) <3
RMS Noise (%) (20 Hz to 20 MHz) <0.5
Peak-to-Peak Noise (%) (20 Hz to 20 MHz) <1
Long Term Power Stability (%) (over 8 hours and ±3°C) <2
Warm-up Time (minutes)…

PowerMax-USB-RS-Sensors-Product-Guide.pdf

PowerMax-USB-RS-Sensors-Product-Guide.pdf


Communication: Pin 2 - Receive Data; Pin 3 - Transmit Data;
Pin 5 - Signal Ground
Required Power: +5 VDC ±5% with less than 100 mV RMS noise
Current draw: <300 mA
Power input connector: 6 mm barrel connector
Power supply: Optional equipment, order #1105557 for UL and…

Innova Sabre brochure

Innova Sabre brochure

…all aspects of
single-line performance.
0 2 MHz
Noise (dBm)
Noise (dBm)
514.5 nm, 10W, TEM00
DC Signal: 0 dBm
Resolution Bandwidth: 300 Hz
Frequency
-105
-55
-25
RMS Noise (%)
514.5 nm 351.1 nm
Frequency
Range
10 Hz…

OBIS GalaxySystem Datasheet COHR 2018.pdf

OBIS GalaxySystem Datasheet COHR 2018.pdf


>55, typical >70
Maximum Power Per Channel (mW) 100
Maximum Total Output Power (mW) <500
RMS Noise (%) (20 Hz to 2 MHz) <0.5
Peak-to-Peak Noise (%) (20 Hz to 20 kHz) <2
Fiber Connector Type (input connectors) FC form-factor, ultra-flat contact FC/UFC with…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…Communication: Pin 2 - Receive Data; Pin 3 - Transmit Data;
Pin 5 - Signal Ground
Required Power: +5 VDC ±5% with less than 100 mV RMS noise
Current draw: <300 mA
Power input connector: 6 mm barrel with 2 mm pin, center positive
Power supply: Optional equipment, order…

Laser Focus World - June 2018

Laser Focus World - June 2018

noise is another important factor
impacting confocal image quality. The intensity noise must be low across a wide
bandwidth (for example, 20 Hz to 20 kHz)
to minimize image noise. This includes
both the average, or root-mean-squared
(RMS) noise and the peak-to-peak noise.

COHR OBIS CellX DS 0117 3.pdf

COHR OBIS CellX DS 0117 3.pdf

…Quality (M2) measured per laser channel using ModeMaster with 90/10 clip levels.
4 Standard alignment. User adjustable
5 RMS Noise and Peak-to-Peak Noise Specifications are per laser channel, during CW operation.
6 Typical power-on delay of 1 minute from cold start.
7 Digital…

OBIS Galaxy Datasheet COHR 2018.pdf

OBIS Galaxy Datasheet COHR 2018.pdf


>55, Typical >70
Maximum Power Per Channel (mW) 120
Maximum Total Output Power (mW) <500
RMS Noise (%) (20 Hz to 2 MHz) <0.5
Peak-to-Peak Noise (%) (20 Hz to 20 kHz) <2
Fiber Connector Type (Input Connectors) FC form-factor, ultra-flat contact FC/UFC with…

COHR OBIS CORE DS 0117 3.pdf

COHR OBIS CORE DS 0117 3.pdf

…hours after warm-up and ±3°C)
Pointing Stability Over Temperature (µrad/°C) <5 <5 <5 <5
RMS Noise (%) (20 Hz to 20 MHz) 0.25 0.25 0.25 0.25
Peak-to-Peak Noise (%) (20 Hz to 20 kHz) <1 <1 <1 <1
Long-Term Power Stability (%) (8 hours, ±3°C) <2 <2 <2…

Genesis-MX-Series-607-639-MTM-End-User

Genesis-MX-Series-607-639-MTM-End-User

…Pointing Tolerance5 (mrad) <10
Polarization Ratio Linear, >100:1
Polarization Direction Horizontal, ±5°
Noise
RMS (%)(10 Hz to 10 MHz)8 <5
RMS (%)(10 Hz to 100 kHz)8 <1
Warm-Up Time (minutes) <10
CDRH Compliant Yes
Operating Voltage (VAC) 100 to…

Genesis-MX-Series-607-639-STM

Genesis-MX-Series-607-639-STM

…Tolerance6 (mrad) <10
Polarization Ratio Linear, >100:1
Polarization Direction Horizontal, ±5°
Noise
RMS (%)(10 Hz to 10 MHz)10 <5
RMS (%)(10 Hz to 100 kHz)10 <1
Power Stability7 (%)(pk-pk) ±<1
Warm-Up Time (minutes) <10
CDRH Compliant…

Powered by Site Search powered by SLI Systems

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions