1 - 10 of 157 Search Results for scan
|
|
|
1.
Laser Spectrum Analyzer System
|
|
... with two concave mirrors. The separation distance between the mirrors is varied slightly using a piezoelectric section of a mirror spacer. A ramp-scan voltage supplied from the Spectrum Analyzer controller drives the piezoelectric. The variation in the mirror spacing changes the cavity resonant spectral ...
Related Searches: fabry perot | fabry perot cavity | spectrum analyzer | spectrum
|
|
|
|
|
2.
ModeMaster PC Scan Head Modular Components
|
|
|
ModeMaster PC Scan Head Modular Components Components for Other Wavelength and Divergence Ranges Allow quick changes to other wavelengths or divergences to suit your needs. Superior Reliability & Performance Lasers and Laser-based Systems Laser Measurement and Control Precision Optics Related Accessories ...
|
|
|
|
|
3.
ModeMaster PC Scan Head Modular Components
|
|
ModeMaster PC Scan Head Modular Components Components for Other Wavelength and Divergence Ranges Allow quick changes to other wavelengths or divergences to suit your needs. Sales Support: 1-800-343-4912 NEW! Smart Finder Tool Search by Sensors and/or Meters. -- select product type -- Find ...
Related Searches: modemaster
|
|
|
|
4.
EOfeb06Semi
(PAGE 1 OF 2)
|
|
|
... etching is completed on one side of a panel, the panel is flipped and the second side is processed. LDI devices of this type currently available can scan panels up to 60cm wide in a single pass, eliminating the need for stepping or stitching. Because LDI does not employ a physical photo-mask, the dimensions ...
|
|
|
|
5.
LTPSWhitePaperFinal_Oct28
(PAGE 4 OF 12)
|
|
|
... long straight lines (see Figure 3). During 2-shot SLS, the panel is scanned using a translation stage. The specific mask design makes it possible to scan the substrate linearly and crystallize each location by just two consecutive laser pulses: the first mask projection produces a pattern of periodic ...
|
|
|
|
|
6.
Beam Diagnostic Cameras
|
|
... -Coupled Device (CCD) sensors or Vidicon tube sensors. CCD sensors have a two-dimensional array of discrete pixels over the image area. Vidicon tubes scan the image plane with an electron beam to determine the image intensity distribution. When possible, use a CCD camera, due to its overall better ...
Related Searches: lasercam | beam view | lasercam hr | lasercam-hr
|
|
|
|
7.
PrecisionMaterialsProcessingwithTaliskerLasers
(PAGE 8 OF 10)
|
|
... 6 demonstrates the removal of 20 nm aluminium from a glass substrate using 1064 nm, 1 µJ pulses with a focused spot size of 20 µm. The galvanometer scan speed for complete thin film removal is 3 m/s, confirming the ability to support high speed processes. The scan speed in these examples was chosen ...
Related Searches: laser scribing of solar panels
|
|
|
|
|
8.
MBR Ring Series
|
|
... setup eliminates the beam-pointing issues common to tuning mirror designs. An automatic wavelength scanning feature (RS-232) is available with a scan range of 30 GHz at a fast tuning speed of 8 GHz/second. The MBR Verdi pumping advantage The pump laser is critical to the performance of every Ti ...
Related Searches: mbr-110 | mbr | ti sapphire | ti sapphire laser
|
|
|
|
|
9.
Skiving Polyimide from Flex Circuits with Q-Switched CO 2 Lasers
|
|
... Y-axis, and the calculated focal spot size from the optical system was 50 microns. A rastered rectangle was produced using various combinations of scan speed, pulse duration, pulse repetition rate, and scan line spacing. Two passes were performed to produce each rectangle. Vector writing was also performed ...
Related Searches: laser engraving
|
|
|
|
10.
EOfeb06Semi
(PAGE 2 OF 2)
|
|
|
... surrounding the mark. German firm Innolas builds soft marking tools for semiconductor manufacturers. The Innolas system uses galvanometer mirrors to scan the focused output from a pulsed laser on to the wafer surface for marking. Innolas use a Coherent PRIMSA series, q-switched, diodepumped Nd:YAG laser ...
|
|