Search
Superior Reliability & Performance

  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
1 - 10 of 255 Search Results for sensor head

1pdf document  HighLight 4000L Preinstallation Manual Best match in this PDF  |  All matches in this PDF
…(detector head plus display console) is necessary. Water cooling is generally required for the detector head at the HighLight 4000L power levels. Make sure to provide adequate cooling for the detector head. Coherent manufactures a wide range of power meters (display consoles and sensor heads). Refer to…
Related Searches: laser wire stripper | evolution manual | water wheel | manual

2pdf document  BeamMasterPC UserManual Oct2011 Best match in this PDF  |  All matches in this PDF
…BeamMaster PC detector head is shown below. The rotating drum contains multiple knife-edge apertures (only one is shown in this diagram). As an aperture passes between the laser beam and the stationary power sensor, there is a period where the entire beam is allowed to reach the sensor. At this point, the…
Related Searches: beam master | computer | user manual | bm-7

3pdf document  Paladin Preinstallation RevAA Best match in this PDF  |  All matches in this PDF
…1104095 Head 1108405 P/S Master w/o Pump Module Assembly 1104093 P/S Slave w/o Pump Module Assembly 1104096 Cable/Tube Set (head cables + Chiller tubes with connectors) 1060685 Pump Module Assembly 1104473 Shipping Crate for Laser Head 1037669 Serial Cable for chiller remote temperature sensor 1116919…
Related Searches: water chiller manual | laser diode modules | laser diode | optishield

4pdf document  COHR LifeSciencesGuide2012revG Best match in this PDF  |  All matches in this PDF
…Cable--Laser Head to Controller 2 m (6.6 ft.) Weights Laser Head 0.33 kg (0.73 lbs.) Analog Controller 0.38 kg (0.83 lbs.) Heatsink (optional) 0.50 kg (1.1 lbs.) Power Supply (optional) 1.66 kg (3.66 lbs.) Cable--Laser Head to Controller 0.52 kg (1.15 lbs.) Detector FieldMax-TO Sensor OP-2VIS Environmental…
Related Searches: dpss 532 200 mw | 488 sapphire | chameleon ultra 2 | line beam

5pdf document  PM-Digital Best match in this PDF  |  All matches in this PDF
…possible configurations. Sensor Connector This is a 25-pin D connector that provides a "smart" interface to the PowerMax series of sensors. During factory calibration of the sensor head, a memory chip inside the connector is programmed with information that specifies the sensor responsivity, max power…
Related Searches: pm-digital | pm-digital driver | calorimeter | pm-5200

6pdf document  Diamond E-400 Series Preinstallation Manual Best match in this PDF  |  All matches in this PDF
…(detector head plus display console) is necessary. Liquid (water) cooling is generally required for the detector head at E-400 Series power levels. Make sure to provide adequate cooling for the detector head. Coherent manufactures a wide range of power meters (display consoles and sensor heads). Refer…
Related Searches: e400i manual | laser chiller | low coolant level | java

7pdf document  DIAMOND E1000 premanual Best match in this PDF  |  All matches in this PDF
…(detector head plus display console) is necessary. Liquid (water) cooling is generally required for the detector head at E-1000 Series power levels. Make sure to provide adequate cooling for the detector head. Coherent manufactures a wide range of power meters (display consoles and sensor heads). Refer…
Related Searches: oem manual | water chiller manual | coherent laser cables | rf module

8pdf document  PowerMaxWhitePaperNewFormatFinal1 Best match in this PDF  |  All matches in this PDF
…Miniaturization Technology Provides Next Generation Laser Power Measurement Traditional laser power measurement instruments, which consist of a sensor head connected to separate meter electronics, can be difficult for system builders to embed into their own equipment, and may even waste valuable space…
Related Searches: dll | usb driver | 4 quadrants

9pdf document  Sapphire LP Family DSrevC 1211 1 Best match in this PDF  |  All matches in this PDF
…(incl. line cable)(2.1 lbs.) Packaged System (head+controller+cable+manual) 1.7 kg (3.7 lbs.) Cable -- Laser Head to Controller 0.3 kg (0.66 lbs.) Part Number Meter FieldMaxTMII-TO 1098579 Sensor PS10Q 1098400 1 Laser-to-laser tolerance.With residual IR emission less than 0.1 mW. 2 Output power is variable…
Related Searches: sapphire windows

1000_HighLight_4000_Pre.book  (PAGE 67 OF 83)
…laser head, place a sturdy table and set up the laser
power measurement equipment.
2. Secure the thermal sensor (detector) to the table, and then turn
on the sensor cooling system.
3. Position the laser head to the sensor such that the focal point is
above the sensor surface…


Page 1 2 3 4 5 6 7 8 9 10 11>> of 26 | Next


Site Search by  Site Search powered by SLI Systems
.