Preinstallation Manual AVIA 355/355-X Laser 5100 Patrick Henry Drive Santa Clara, CA 95054 AVIA 355/AVIA 355-X Laser Operator's Manual ii This document is copyrighted with all rights reserved. Under the copyright laws, this document may not be copied in whole or in part or reproduced in any other media ... Related Searches:avia 355 20 | laser danger sign | avia 355 manual | avia-x
... :nn ?SPS:nn nn= The spot number of the THG crystal spot you wish to check. 0 if the spot status is GOOD. 2 if the spot status is USED. PRINT TEMP SERVO TIGHT LOCK STATUS ?TSTLS Indicates is all temperature servos are within 0.1ºC of set temperature. 0 = Not within 0.1ºC 1 = within 0.1ºC. PRINT THG DRIVE ... Related Searches:avia manual
External Computer Control 27 PRINT TEMP SERVO TIGHT LOCK STATUS ?TSTLS Indicates is all temperature servos are within 0.1ºC of set temperature. 0 = Not within 0.1ºC 1 = within 0.1ºC. PRINT FHG DRIVE ?FHGD Returns FHG temperature servo drive setting. PRINT FHG OPTIMIZE ?FHGO Returns the status of the ...
... = 0 aborts optimization. n = 1 initiates optimization. (available only in continuous mode, internal trigger only). DIODE2 TEMP=nn.nn D2T=nn.nn Closes servo and sets laser diode 2 temperature in degrees Centigrade. The allowed temperature range is 10.00 to 40.00°C. DIOPTRIC OPTIMIZE POWER=n DOP=n Initiates ...
... 2 degradation rate and diode 2 hours. PRINT DIODE2 RATED CURRENT ?D2RC Returns the set maximum current of diode 2 in Amps as nn.nn. PRINT DIODE2 SERVO STATUS ?D2SS Returns the status of diode 2 temperature servo: 0 if the servo is OPEN. 1 if the servo is LOCKED. 2 if the servo is SEEKING. 3 if the servo ...
Preinstallation Manual AVIA 266 Laser 5100 Patrick Henry Drive Santa Clara, CA 95054 AVIA 266 Laser Operator's Manual ii This document is copyrighted with all rights reserved. Under the copyright laws, this document may not be copied in whole or in part or reproduced in any other media without the ... Related Searches:266 | laser danger sign | fap system manual | avia manual
... = 0 aborts optimization. n = 1 initiates optimization. (available only in continuous mode, internal trigger only). DIODE2 TEMP=nn.nn D2T=nn.nn Closes servo and sets laser diode 2 temperature in degrees Centigrade. The allowed temperature range is 10.00 to 40.00°C. DIOPTRIC OPTIMIZE POWER=n DOP=n Initiates ...
... 2 degradation rate and diode 2 hours. PRINT DIODE2 RATED CURRENT ?D2RC Returns the set maximum current of diode 2 in Amps as nn.nn. PRINT DIODE2 SERVO STATUS ?D2SS Returns the status of diode 2 temperature servo: 0 if the servo is OPEN. 1 if the servo is LOCKED. 2 if the servo is SEEKING. 3 if the servo ...