1 - 10 of 116 Search Results for sigma

1pdf document  ExcimerProductGuide2011 Best match in this PDF  |  All matches in this PDF
…/500 200/500 Max. Pulse Energy (mJ) 2 8 12 5 Stabilized Pulse Energy (mJ) 1 5 8 4 Average Pulse Power1 0.2/0.5 1/2.5 1.6/4 0.8/2 Energy Stability1 (sigma, %) 2/3 2/3 2/3 2/3 Beam Dimensions (FWHM,V x H, mm2) 6 x 3 6 x 3 6 x 3 6 x 3 Beam Divergence (FWHM,V x H, mrad2) 3 x 1.5 3 x 1.5 3 x 1.5 3 x 1.5 Pulse…
Related Searches: excimer manual | premix gas | krf laser | excimer laser

2pdf document  LineBeam DS 0710 Best match in this PDF  |  All matches in this PDF
…(±10) (±10) Homogeneity Long Axis (at 96% from mean value) Specification <_1.4%, 2 sigma <_1.4%, 2 sigma <_1.4%, 2 sigma <_1.4%, 2 sigma Typical Value <_1.0%, 2 sigma <_1.0%, 2 sigma <_1.0%, 2 sigma <_1.0%, 2 sigma Steepness short axis (µm) <_100 <_100 <_100 <_100 (90% to 10%), open slit Depth of focus…
Related Searches: oled | homogenizer optics | pulse duration extender

3pdf document  HighRep-RateExcimerLasersforMicromachingRev2 Best match in this PDF  |  All matches in this PDF
…energy stability at 16 mJ in KrF operation is specified with < 2% Sigma. Figure 1 shows a run over 50 million pulses without a total laser gas exchange. The energy stability is nearly constant at a typical achieved value of 0.5% Sigma. Figure 1: Typical energy stability KrF over 50 million pulses 16…
Related Searches: resonator | arf laser | excimer laser | krf laser

4IndyStar_DS  (PAGE 2 OF 2)

Homogeneity Long Axis (at 96% from mean value)
Specification <_1.4%, 2 sigma <_1.4%, 2 sigma <_1.4%, 2 sigma <_1.4%, 2 sigma
Typical Value <_1.0%, 2 sigma <_1.0%, 2 sigma <_1.0%, 2 sigma <_1.0%, 2 sigma
Steepness short axis (µm) <_100 <_100 <_100 <_100
(90% to 10%), open slit…

5ExcimerProductGuide2008.qxd  (PAGE 37 OF 54)

Homogeneity Long Axis (at 96% from mean value)
Specification <_1.4%, 2 sigma <_1.4%, 2 sigma <_1.4%, 2 sigma <_1.4%, 2 sigma
Typical Value <_1.0%, 2 sigma <_1.0%, 2 sigma <_1.0%, 2 sigma <_1.0%, 2 sigma
Steepness short axis (µm) <_100 <_100 <_100 <_100
(90% to 10%), open slit…

6pdf document  ExciStarXS200500 DSrevA 0910 Best match in this PDF  |  All matches in this PDF
…Hz E(U) 500 Hz Sigma(U) 200 Hz Sigma(U) 500 Hz High Voltage (V) PulseEnergy(mJ) EnergyStability(sigma,%) 0 4 8 12 16 20 700 800 900 1000 1100 1200 1300 1400 1500 0 1 2 3 4 5 6 E(U) 200 Hz E(U) 500 Hz Sigma(U) 200 Hz Sigma(U) 500 Hz High Voltage (V) PulseEnergy(mJ) EnergyStability(sigma,%) System Specifications…
Related Searches: almeta | excistar 200 | excistar xs 200

7ExciStarXS_200&500_DS  (PAGE 2 OF 2)

Sigma(U) 200 Hz
Sigma(U) 500 Hz
High Voltage (V)
PulseEnergy(mJ)
EnergyStability(sigma,%)
0
4
8
12
16
20
700 800 900 1000 1100 1200 1300 1400 1500
0
1
2
3
4
5
6
E(U) 200 Hz
E(U) 500 Hz
Sigma(U)…
Related Searches: excistar 200

8pdf document  300WXeClExcimerLaserAnnealingRev2 Best match in this PDF  |  All matches in this PDF
…deviation over a 40 million pulses run is shown in Figure 2. The LAMBDA STEEL 1000 energy deviation is specified with Sigma < 2.5%, however, usually the average deviation is below 1 % (1 Sigma). SPIE USE, V. 2 5004-10 (p.2 of 8) / Color: No / Format: A4/ AF: A4 / Date: 2002-12-23 08:08:15 Please verify that…
Related Searches: silicon annealing | annealing | excimer laser annealing | ludolf herbst

9pdf document  Paper LPM2004Rev2 Best match in this PDF  |  All matches in this PDF
…energy stability of a COMPex with smooth ceramic preionization measured over 1000 laser pulses at a wavelength of 248 nm. A typical standard deviation sigma of ca. 1 % is achieved at high pulse energies. 3.2 Beam Homogeneity Excimer lasers have typically a rectangular beam profile, whereas the long axis…
Related Searches: halogen | ceramic | excimer gas | compex

10HighRep-RateExcimerLasersforMicromachingRev2.pdf  (PAGE 4 OF 9)
…stability of the NOVATEX is specified with < 100 µrad Sigma. Figure 5 shows a typical beam pointing
stability of 16 µrad Sigma. In Figure 6 the beam position stability is shown. The specification is < 150 µm, however, a
value of < 5 µm Sigma in both horizontal and vertical could be achieved…
Related Searches: pointing stability