Search for Lasers, Laser Systems, Laser Measurment, Laser Service Coherent Inc., Worldwide websites Coherent Inc., calendar of events Coherent Inc., office locator Coherent Inc., Service Centers
     > Search
Search Coherent
Coherent Inc.
Superior Reliability & Performance
  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
Please enter a search phrase.

1 - 10 of 19 Search Results for small frame heat exchanger
Search Suggestions: heat exchanger | innova 300 manual | chiller | laserpure 20 | laserpure | innova 90 | recirculating chiller | chiller manual | innova 70 user manual | laserpure 40

1pdf document  Laser_Cooling_Water_Guidelines Best match in this PDF  |  All matches in this PDF
... . 2 Specifications and Recommendations. 3 Water Flow Guidelines . 3 Water Temperature Specification . 5 Temperature Sensors. 5 Ambient Dew Point . 5 Heat Loads . 6 Water Quality. 7 Guidelines . 7 Construction Materials for Cooling Systems. 9 Recommended Pipe Size . 9 Types of Water Systems. 10 Flow-Through ...
Related Searches: chiller | innova 300 manual | innova 90 | recirculating chiller

2pdf document  Innova_322C_Preinstallation Best match in this PDF  |  All matches in this PDF
... . 11 Power Supply Installation. 11 Power Connection. 11 Umbilical Connections . 12 Water Connections. 14 External Interlock . 15 External Switch. 16 Heat Exchanger Control (option). 16 Remote Control Module Connection. 16 Rotating the Umbilical on the Laser Head. 16 Rotating the Umbilical on the Power ...
Related Searches: innova 300 manual | innova 70 user manual | q switch | field mate

3pdf document  Laser_Cooling_Water_Guidelines  (PAGE 4 OF 34)
... iv Appendix B: Operating Tips . 26 Appendix C: Bibliography. 27 LIST OF ILLUSTRATIONS 1. Flow Test Fixture. 12 2. Plant Water Requirements for Small Frame Heat Exchanger (17 kW heat load) . 21 3. Plant Water Requirements for Small Frame Heat Exchanger (18 kW heat load) . 22 4. Plant Water Requirements ...
Related Searches: heat exchanger

4pdf document  Laser_Cooling_Water_Guidelines  (PAGE 26 OF 34)
Innova Ion Laser Systems 20 The LaserPure 5i This water-to-air chiller is recommended for use with Coherent lasers with a heat load of up to 5 kilowatts. The LaserPure 20 This heat exchanger is recommended for use with Coherent lasers with a heat load of up to 20 kilowatts. The LaserPure 40 This heat ...
Related Searches: laserpure 5

5pdf document  Laser_Cooling_Water_Guidelines  (PAGE 30 OF 34)
Weights and Dimensions The Small Frame Heat exchanger weights and Dimensions are given in Table 10. Sabre Heat Exchanger All Sabre laser systems include an integral Heat Exchanger which is powered and controlled by the Sabre power supply via an interface cable. Please refer to the Sabre Operators manual ...

6pdf document  Laser_Cooling_Water_Guidelines  (PAGE 27 OF 34)
Water Cooling Guidelines 21 The use of this heat exchanger also improves beam pointing and power stability since the heat exchanger regulates the cooling water temperature within ±1°C (±1.8°F). The plant water required for the water to water integrated heat exchanger can be either tap water or any ...

7pdf document  Laser_Cooling_Water_Guidelines  (PAGE 3 OF 34)
... . 2 Specifications and Recommendations. 3 Water Flow Guidelines . 3 Water Temperature Specification . 5 Temperature Sensors. 5 Ambient Dew Point . 5 Heat Loads . 6 Water Quality. 7 Guidelines . 7 Construction Materials for Cooling Systems. 9 Recommended Pipe Size . 9 Types of Water Systems. 10 Flow-Through ...
Related Searches: chiller | water chiller

8pdf document  Laser_Cooling_Water_Guidelines  (PAGE 28 OF 34)
Innova Ion Laser Systems 22 Figure 3. Plant Water Requirements for Small Frame Heat Exchanger (18 kW heat load) Figure 4. Plant Water Requirements for Small Frame Heat Exchanger (22 kW heat load) Minim um Plant Water Requirem ents Heat Load: 18 KW 0.0 5.0 10.0 15.0 20.0 25.0 30.0 5.0 6.0 7.0 8.0 9 ...
Related Searches: innova 70

9pdf document  Innova90C_preinstallation  (PAGE 24 OF 32)
... for 30 VAC, 12 Amps (maximum). It is not internally protected by fuses or other overcurrent protection devices. Refer to Figure 3 for TB1 pin-outs. Heat Exchanger Control (option) On the rear panel of the Innova power supply is a plug labeled TO HEAT EXCHANGER(Figure 3, Item 15). An interconnect cable ...
Related Searches: heat exchanger

10pdf document  Innova_300C_preinstallation  (PAGE 24 OF 30)
... for 30 VAC, 12 Amps (maximum). It is not internally protected by fuses or other overcurrent protection devices. Refer to Figure 3 for TB1 pin-outs. Heat Exchanger Control (option) On the rear panel of the Innova power supply is a plug labeled TO HEAT EXCHANGER(Figure 3, Item 15). An interconnect cable ...


Search Suggestions: heat exchanger | innova 300 manual | chiller | laserpure 20 | laserpure | innova 90 | recirculating chiller | chiller manual | innova 70 user manual | laserpure 40
Page 1 2 of 2 | Next


Site Search by  Site Search powered by SLI Systems