Search
Superior Reliability & Performance

  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
1 - 10 of 247 Search Results for spectral width

1pdf document  pdf 127 Best match in this PDF  |  All matches in this PDF
…order of the grating were recorded on VUVsensitive photographic plates and measured with a high-precision optical comparator. To estimate the spectral width of the strongest lasing line (157.63 nm), we took a series of exposures of this line in the 3rd order of the grating. In Table 1 and Fig. 3 we…
Related Searches: compex 205 | wood's horn | wood | compex

2pdf document  EnergyMax-USB-RS UserManual 1186243RevAA Best match in this PDF  |  All matches in this PDF
…pulse width linearity error when using a sensor at its maximum specified pulse width. This error is less than 1%. At pulse widths less than 10 µs this error is negligible and is less than 0.5%. (The J-50MB-IR sensor has a slightly higher pulse width linearity specification of +/- 1.5%.) Spectral Response…
Related Searches: pulse width | lab max | 1064 532 | spectral correction

3pdf document  2009 LMCCatalog Best match in this PDF  |  All matches in this PDF
…pulses with a thermopile is necessary when the laser pulse width exceeds the maximum pulse width rating of pyroelectric sensors. Pyroelectric sensors are typically limited to maximum pulse widths in the millisecond range.When the pulse width exceeds milliseconds, a thermopile is a good solution. A good…
Related Searches: lm 1 | 532 laser | lm-45 htd | verdi-v5

4pdf document  EnergyMaxSensors UserManual RevAB Best match in this PDF  |  All matches in this PDF
…pulse width linearity error when using a sensor at its maximum specified pulse width. This error is less than 1%. At pulse widths less than 10 µs this error is negligible and is less than 0.5%. (The J-50MB-IR sensor has a slightly higher pulse width linearity specification of +/- 1.5%.) Spectral Response…
Related Searches: field max ii top power energy meter | pyroelectric sensor | j-50mb-yag | j50

5pdf document  COHR LMC 2010-2011catalog Best match in this PDF  |  All matches in this PDF
…pulses with a thermopile is necessary when the laser pulse width exceeds the maximum pulse width rating of pyroelectric sensors. Pyroelectric sensors are typically limited to maximum pulse widths in the millisecond range.When the pulse width exceeds milliseconds, a thermopile is a good solution. A good…
Related Searches: j100 | lm-2 vis | lm-45 htd | laser check power meter

6pdf document  LMC 2011catalog 0411 Best match in this PDF  |  All matches in this PDF
…pulses with a thermopile is necessary when the laser pulse width exceeds the maximum pulse width rating of pyroelectric sensors. Pyroelectric sensors are typically limited to maximum pulse widths in the millisecond range.When the pulse width exceeds milliseconds, a thermopile is a good solution. A good…
Related Searches: j100 | pm150 19b | pm150 | high speed driver

7pdf document  EnergyMaxGuide FINAL Best match in this PDF  |  All matches in this PDF
…or perform your own spectral calibrations Model J-50MB-YAG J-50MB-IR Energy Range 2.4 mJ to 3J1 3.2 mJ to 3J Noise Equivalent Energy (µJ) <240 <320 Wavelength Range (µm) 0.266 to 2.1 0.5 to 3.0 Maximum Beam Size (mm) 35 30 Maximum Average Power (W) 20 15 Maximum Pulse Width (µs) 340 1000 Maximum…
Related Searches: laser power and energy meters | j-10mt | j-10si-he | j25mb-le

8pdf document  EnergyMaxGuide revA 10 FINAL Best match in this PDF  |  All matches in this PDF
spectral calibrations Model J-50MB-YAG J-50MB-IR J-25MB-IR Energy Range 1.5 mJ to 3J1 1.0 mJ to 3J 1.5 mJ to 3J Noise Equivalent Energy (µJ) <50 <100 <50 Wavelength Range (µm) 0.266 to 2.1 0.5 to 3.0 0.532 to 2.1 Maximum Beam Size (mm) 35 30 12.5 Maximum Average Power (W) 20 15 20 Maximum Pulse Width
Related Searches: j 50 | j-10si | photodiode sensor | energy

9pdf document  pdf 148 Best match in this PDF  |  All matches in this PDF
…of the position and width of the plasma, as well as the spectral emission. This stability of the source emission is a critical parameter in the EUV lithography process. The result of such a measurement is shown in Fig. 4 for the stability of the emission in the same three spectral regions shown in the…
Related Searches: spectral correction | photo detector | excimer laser annealing | lambda physik krf

10pdf document  tech bullfourier transform Best match in this PDF  |  All matches in this PDF
…interferometric) or spectral measurements. Autocorrelations suffer from the fact that the autocorrelation function, not the pulse shape is measured and the shape of the resulting autocorrelation is strongly dependent on the pulse shape. Even a relatively simple pulse parameter such as Full Width Half Maximum…
Related Searches: pulse stretcher


Page 1 2 3 4 5 6 7 8 9 10 11>> of 25 | Next