1 - 10 of 33 Search Results for thg crystal
Search Suggestions: bbo crystal | avia 355 x | permalign | thermeq | eo modulator | 266nm cw laser | 355 nm | indigo-s | ti sapphire | harmonic generator 9300

1pdf document  BBO_DS Best match in this PDF  |  All matches in this PDF
BBO Beta Barium Borate - -BaB2O4 Beta Barium Borate ( -BaB2O4 ), or BBO, is one of the most versatile nonlinear optical crystal materials available. BBO is most commonly used for second or higher order harmonic generation of Nd:YAG, Ti:Sapphire, Argon Ion and Alexandrite lasers. BBO's Unique Combination ...
Related Searches: bbo crystal

2AVIA Technical Overview
... better than any competitor. Constant Power Over Time – Over time power degradation of the third harmonic generation (THG) crystal, results in power degradation in a UV laser.  The AVIA uses a large THG crystal with multiple spot positionsdesign overcomes this by using a ...
Related Searches: avia 355 x | permalign | thermeq | 266nm cw laser

3pdf document  IndigoS_DSrevA_final Best match in this PDF  |  All matches in this PDF
Solid-State, Tunable, Ti:Sapphire Laser FEATURES · All-solid-state design with diode pumping · Tunable at SHG, THG, and FHG of Ti:Sapphire gain bandwidth · <1 cm-1 linewidth across entire tuning range · Computer-controlled wavelength scanning option with 0.1 cm-1 step size · TEM00 beam profile ...
Related Searches: indigo-s | ti sapphire | indigo

4Low Power
... mirror will automatically move through its entire range, and settle at the position, which results in the highest laser power. Optimize the SHG, THG, Diode 1 and Diode 2 temperatures. The temperatures at which the SHG, THG, Diode 1 and Diode 2 perform most efficiently are determined when the laser is ...

5pdf document  HarmonicGen_9300_DS Best match in this PDF  |  All matches in this PDF
... the MIRA® 900 Modelocked Titanium:Sapphire (Ti:S) Laser Systems into the blue and ultraviolet wavelength range. Using frequency doubling in an LBO crystal and subsequent sum-frequency mixing in a BBO crystal, the Harmonic Generator 9300 covers the wavelength ranges 350 to 500 nm and 240 to 320 nm. FEATURES ...
Related Searches: harmonic generator 9300 | mira shg | doubler | mira

6pdf document  Avia_355-355X_Preinstallation  (PAGE 34 OF 38)
AVIA 355/AVIA 355-X Laser Preinstallation Manual 28 PRINT SPOT STATUS:nn ?SPS:nn nn= The spot number of the THG crystal spot you wish to check. 0 if the spot status is GOOD. 2 if the spot status is USED. PRINT TEMP SERVO TIGHT LOCK STATUS ?TSTLS Indicates is all temperature servos are within 0.1C of ...

7pdf document  Avia_355-355X_Preinstallation  (PAGE 26 OF 38)
... : 3 to 300000 Hz. RESET SYSTEM=1 RESET=1 Stops the internal watchdog timer and causes the system to reboot. Use this command only when necessary. SET CRYSTAL WARNING INTERVAL CWI=nnnn Sets the warning time interval for each crystal spot in hours (10 to 1000 hours). Default is 100 hours. SET SPOT POSITION ...

8Beam Quality
... automatic optimization of the ThermaTrack mirror, which will result in optimum laser power and mode quality. Optimize the temperatures of the SHG, THG and diodes. Verify the laser rods are at the correct setpoint temperature. It is unlikely that reoptimizing the temperatures of the crystals and diodes ...
Related Searches: mirror

9pdf document  Avia_355-355X_Preinstallation Best match in this PDF  |  All matches in this PDF
Preinstallation Manual AVIA 355/355-X Laser 5100 Patrick Henry Drive Santa Clara, CA 95054 AVIA 355/AVIA 355-X Laser Operator's Manual ii This document is copyrighted with all rights reserved. Under the copyright laws, this document may not be copied in whole or in part or reproduced in any other media ...
Related Searches: avia 355 10 | avia 355-3000 | avia 355-x | avia manual

10pdf document  Avia_266_Preinstallation  (PAGE 25 OF 38)
... : 3 to 300000 Hz. RESET SYSTEM=1 RESET=1 Stops the internal watchdog timer and causes the system to reboot. Use this command only when necessary. SET CRYSTAL WARNING INTERVAL CWI=nnnn Sets the warning time interval for each crystal spot in hours (10 to 1000 hours). Default is 100 hours. SET SPOT POSITION ...