1 - 10 of 33 Search Results for thg crystal
|
|
1.
BBO_DS
|
Best match in this PDF
|
All matches in this PDF
|
BBO Beta Barium Borate - -BaB2O4 Beta Barium Borate ( -BaB2O4 ), or BBO, is one of the most versatile nonlinear optical crystal materials available. BBO is most commonly used for second or higher order harmonic generation of Nd:YAG, Ti:Sapphire, Argon Ion and Alexandrite lasers. BBO's Unique Combination ...
Related Searches: bbo crystal
|
|
|
|
|
2.
AVIA Technical Overview
|
|
... better than any competitor. Constant Power Over Time – Over time power degradation of the third harmonic generation (THG) crystal, results in power degradation in a UV laser. The AVIA uses a large THG crystal with multiple spot positionsdesign overcomes this by using a ...
Related Searches: avia 355 x | permalign | thermeq | 266nm cw laser
|
|
|
|
|
4.
Low Power
|
|
|
... mirror will automatically move through its entire range, and settle at the position, which results in the highest laser power. Optimize the SHG, THG, Diode 1 and Diode 2 temperatures. The temperatures at which the SHG, THG, Diode 1 and Diode 2 perform most efficiently are determined when the laser is ...
|
|
|
|
6.
Avia_355-355X_Preinstallation
(PAGE 34 OF 38)
|
|
|
AVIA 355/AVIA 355-X Laser Preinstallation Manual 28 PRINT SPOT STATUS:nn ?SPS:nn nn= The spot number of the THG crystal spot you wish to check. 0 if the spot status is GOOD. 2 if the spot status is USED. PRINT TEMP SERVO TIGHT LOCK STATUS ?TSTLS Indicates is all temperature servos are within 0.1C of ...
|
|
|
|
7.
Avia_355-355X_Preinstallation
(PAGE 26 OF 38)
|
|
|
... : 3 to 300000 Hz. RESET SYSTEM=1 RESET=1 Stops the internal watchdog timer and causes the system to reboot. Use this command only when necessary. SET CRYSTAL WARNING INTERVAL CWI=nnnn Sets the warning time interval for each crystal spot in hours (10 to 1000 hours). Default is 100 hours. SET SPOT POSITION ...
|
|
|
|
|
8.
Beam Quality
|
|
... automatic optimization of the ThermaTrack mirror, which will result in optimum laser power and mode quality. Optimize the temperatures of the SHG, THG and diodes. Verify the laser rods are at the correct setpoint temperature. It is unlikely that reoptimizing the temperatures of the crystals and diodes ...
Related Searches: mirror
|
|
|
|
10.
Avia_266_Preinstallation
(PAGE 25 OF 38)
|
|
|
... : 3 to 300000 Hz. RESET SYSTEM=1 RESET=1 Stops the internal watchdog timer and causes the system to reboot. Use this command only when necessary. SET CRYSTAL WARNING INTERVAL CWI=nnnn Sets the warning time interval for each crystal spot in hours (10 to 1000 hours). Default is 100 hours. SET SPOT POSITION ...
|
|