1 - 10 of 12 Search Results for thyratron switch
|
|
|
3.
NaturePhotonics20-10-50 thLaserAnn_Annealing.pdf
(PAGE 1 OF 1)
|
|
…-voltage semiconductor switching technology, combined with magnetic isolators and pulse transformers to achieve the required discharge voltages, eliminated the need for thyratron switches by the end of the 1990s. The replacement of the thyratron switch by its maintenancefree…
Related Searches: polysilicon annealing
|
|
|
|
5.
LTJ Excimer 0607
|
Best match in this PDF
|
All matches in this PDF
|
…innovation was replacement of the vacuum-based thyratron used to switch the high voltage discharge with a solid state switch. in high uptime 24/7 industrial applications the thyratron often needed replacement every few months, whereas the solid state power switch has a lifetime considerably longer than the…
Related Searches: ceramic | krf | thyratron
|
|
|
|
|
6.
Paper Title
(PAGE 2 OF 8)
|
|
2.1 Solid-State Pulsed High Voltage Switch Conventional high-pulse energy excimer lasers incorporate thyratrons in their electrical circuits capable of high-voltage switching at up to 32 kV within several nanoseconds. With regard to an enhancement of stressed electrical components lifetimes…
Related Searches: thyratron
|
|
|
|
|
7.
REL_TuiLaserReprint.pdf
(PAGE 3 OF 5)
|
|
…and 248 nm. Another important development has been the use of solid-state switches to replace the gas thyratrons formerly used to switch the high voltage. This has eliminated thyratron failure in industrial excimers. In addition, manufacturers of excimers have developed…
Related Searches: ophthalmic argon laser
|
|
|
|
|
8.
NaturePhotonics20-10-50 thLaserAnn_Annealing.pdf
(PAGE 1 OF 1)
|
|
…-voltage semiconductor switching technology, combined with magnetic isolators and pulse transformers to achieve the required discharge voltages, eliminated the need for thyratron switches by the end of the 1990s. The replacement of the thyratron switch by its maintenancefree…
Related Searches: polysilicon annealing
|
|
|
|
|
9.
LTJ_Excimer_0607.pdf
(PAGE 1 OF 3)
|
|
…replacement of the vacuum-based thyratron used to switch the high voltage discharge with a solid state switch. in high uptime 24/7 industrial applications the thyratron often needed replacement every few months, whereas the solid state power switch has a lifetime considerably…