Ask a Question
Coherent
Search Results
Refine
1 - 12 of 21 Products for 'uv cvarm' Page 1 of 2 |

uv cvarm

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…in.) 45.7 mm (1.8 in.) 46 mm (1.8 in.) C-Mount Thread VARMC-VARM and UV C-VARM BCUBE and UV-BCUBE Attenuation Optics for Cameras Beam Diagnostic Accessories 0.12 + 0.12 + 0.12 + 0.12 + 0.12 + 0.12 = 0.25 Model VARM C-VARM UV C-VARM BCUBE UV-BCUBE BARREL SET (Barrels, 3 C-Mount Flanges) Wavelength…

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…in.) 45.7 mm (1.8 in.) 46 mm (1.8 in.) C-Mount Thread VARMC-VARM and UV C-VARM BCUBE and UV-BCUBE Attenuation Optics for Cameras Beam Diagnostic Accessories 0.12 + 0.12 + 0.12 + 0.12 + 0.12 + 0.12 = 0.25 Model VARM C-VARM UV C-VARM BCUBE UV-BCUBE BARREL SET (Barrels, 3 C-Mount Flanges) Wavelength…

C24 Program

C24 Program

…+ PS19 Accessories Beam Diagnostic Accessories BeamCube Fixed Attenuator - BCUBE Continuous Variable Attenuator - C-VARM UV Continuous Variable Attenuator - UV-C-VARM UV BeamCube Fixed Attenuator - UV-BCUBE Power Sensor Accessories 1000:1 Attentuator FC/PC Type Connector Thermal SmartSensor…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…in.) 45.7 mm (1.8 in.) 46 mm (1.8 in.) C-Mount Thread VARMC-VARM and UV C-VARM BCUBE and UV-BCUBE Attenuation Optics for Cameras Beam Diagnostic Accessories 0.12 + 0.12 + 0.12 + 0.12 + 0.12 + 0.12 = 0.25 Model VARM C-VARM UV C-VARM BCUBE UV-BCUBE BARREL SET (Barrels, 3 C-Mount Flanges) Wavelength…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…in.) 45.7 mm (1.8 in.) 46 mm (1.8 in.) C-Mount Thread VARMC-VARM and UV C-VARM BCUBE and UV-BCUBE Attenuation Optics for Cameras Beam Diagnostic Accessories 0.12 + 0.12 + 0.12 + 0.12 + 0.12 + 0.12 = 0.25 Model VARM C-VARM UV C-VARM BCUBE UV-BCUBE BARREL SET (Barrels, 3 C-Mount Flanges) Wavelength…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…in.) 45.7 mm (1.8 in.) 46 mm (1.8 in.) C-Mount Thread VARMC-VARM and UV C-VARM BCUBE and UV-BCUBE Attenuation Optics for Cameras Beam Diagnostic Accessories 0.12 + 0.12 + 0.12 + 0.12 + 0.12 + 0.12 = 0.25 Model VARM C-VARM UV C-VARM BCUBE UV-BCUBE BARREL SET (Barrels, 3 C-Mount Flanges) Wavelength…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…86 SMA-Type Connector 42, 63 Soft Carrying Cases 21 Thermal SmartSensor Adapter 9, 62 Model Name Page Number UV-BCUBE 104-105 UV/VIS 33, 34 UV C-VARM 104-105 VARM 104-105 WaveMaster 94, 116-117 Wand UV/VIS 33 Wand UV/VIS Adapters 42 POWER & ENERGY Custom & OEM BEAM DIAGNOSTICS CALIBRATION…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…86 SMA-Type Connector 42, 63 Soft Carrying Cases 21 Thermal SmartSensor Adapter 9, 62 Model Name Page Number UV-BCUBE 104-105 UV/VIS 33, 34 UV C-VARM 104-105 VARM 104-105 WaveMaster 94, 116-117 Wand UV/VIS 33 Wand UV/VIS Adapters 42 POWER & ENERGY Custom & OEM BEAM DIAGNOSTICS CALIBRATION…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…86 SMA-Type Connector 42, 63 Soft Carrying Cases 21 Thermal SmartSensor Adapter 9, 62 Model Name Page Number UV-BCUBE 104-105 UV/VIS 33, 34 UV C-VARM 104-105 VARM 104-105 WaveMaster 94, 116-117 Wand UV/VIS 33 Wand UV/VIS Adapters 42 POWER & ENERGY Custom & OEM BEAM DIAGNOSTICS CALIBRATION…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…be removed. The Continuously Variable Attenuator Modules (C-VARM and UV C-VARM) contain two wedge attenuators that are continuously variable and a step attenuator that allows attenuation from 107:1 down to 3000:1.The C-VARM and UV C-VARM can be finely adjusted to achieve both precise attenuation…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…be removed. The Continuously Variable Attenuator Modules (C-VARM and UV C-VARM) contain two wedge attenuators that are continuously variable and a step attenuator that allows attenuation from 107:1 down to 3000:1.The C-VARM and UV C-VARM can be finely adjusted to achieve both precise attenuation…

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

Laser-Measurement-and-Control-Catalog FORMFIRST.pdf

…be removed. The Continuously Variable Attenuator Modules (C-VARM and UV C-VARM) contain two wedge attenuators that are continuously variable and a step attenuator that allows attenuation from 107:1 down to 3000:1.The C-VARM and UV C-VARM can be finely adjusted to achieve both precise attenuation…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions