Ask a Question
Coherent
Search Results
Refine
1 - 12 of 42 Products for 'variable laser attenuator' Page 1 of 4 |

variable laser attenuator

COHERENT LMC 2016-2017 Catalog .pdf

COHERENT LMC 2016-2017 Catalog .pdf

…be introduced to the beam: t = Transmission Value t = 1.00 t = 1.00 t = 1.00 Laser Beamline C-Mount Thread 50 mm (1.97 in.) 70 mm (2.76 in.) 86 mm (3.39 in.) 40 mm (1.57 in.) IN FIXED ATTENUATION VARIABLE ATTENUATION MAX MIN MAX MIN OUT 79.4 mm (3.13 in.) 63.5 mm (2.5 in.) 58.7 mm (2.3 in.) 57.1…

Picosecond laser

Picosecond laser

…?PRENABLE INT -- Get power regulation enable state Returns the variable attenuator control mode (0: open loop, set transmission; 1: closed loop, set power) PRENABLE INT 0 1 -- Set power regulation enable state Sets the variable attenuator control mode (0: open loop, set transmission; 1: closed loop,…

Picosecond laser

Picosecond laser

…?PRENABLE INT -- Get power regulation enable state Returns the variable attenuator control mode (0: open loop, set transmission; 1: closed loop, set power) PRENABLE INT 0 1 -- Set power regulation enable state Sets the variable attenuator control mode (0: open loop, set transmission; 1: closed loop,…

Picosecond laser

Picosecond laser

…(which will be actively regulated by the attenuator). The maximum of this value can be checked by sending ?PATTSETMAX l PRENABLE=1 to set the control mode of the variable attenuator to closed loop (regulated) l ?PATTSET to query the power after the attenuator l RL=nnn defines the analog level of…

UV Optical Components

UV Optical Components

UV Optical Components Making the most of a UV laser beam. Contact Us About This Product close PRICE HERE Attenuators Attenuator Module, Manual Variable attenuation substrate 60 x 35 x 2 mm 3 with inverse characteristic for high thermal stability. Compensator plate 60 x 35 x 2 mm 3 to compensate for…

C24 Program

C24 Program

…S-1551 FieldMaxII-TO + PS19 Accessories Beam Diagnostic Accessories BeamCube Fixed Attenuator - BCUBE Continuous Variable Attenuator - C-VARM UV Continuous Variable Attenuator - UV-C-VARM UV BeamCube Fixed Attenuator - UV-BCUBE Power Sensor Accessories 1000:1 Attentuator FC/PC Type Connector Thermal…

Picosecond laser

Picosecond laser

…?PATT FLT Get attenuator power ?PATTSET FLT Returns the closed-loop attenuator set power PATTSET FLT Sets the closed-loop attenuator set power ?PATTSETMAX FLT Returns the maximum allowed attenuator set power in closed loop mode ?PRENABLE INT Returns the variable attenuator control mode (0:…

Picosecond laser

Picosecond laser

…?PATT FLT Get attenuator power ?PATTSET FLT Returns the closed-loop attenuator set power PATTSET FLT Sets the closed-loop attenuator set power ?PATTSETMAX FLT Returns the maximum allowed attenuator set power in closed loop mode ?PRENABLE INT Returns the variable attenuator control mode (0:…

Picosecond laser

Picosecond laser

…?PATT FLT Get attenuator power ?PATTSET FLT Returns the closed-loop attenuator set power PATTSET FLT Sets the closed-loop attenuator set power ?PATTSETMAX FLT Returns the maximum allowed attenuator set power in closed loop mode ?PRENABLE INT Returns the variable attenuator control mode (0:…

Picosecond laser

Picosecond laser

…(which will be actively regulated by the attenuator). The maximum of this value can be checked by sending ?PATTSETMAX l PRENABLE=1 to set the control mode of the variable attenuator to closed loop (regulated) l ?PATTSET to query the power after the attenuator l RL=nnn defines the analog level of…

Picosecond laser

Picosecond laser

…(which will be actively regulated by the attenuator). The maximum of this value can be checked by sending ?PATTSETMAX l PRENABLE=1 to set the control mode of the variable attenuator to closed loop (regulated) l ?PATTSET to query the power after the attenuator l RL=nnn defines the analog level of…

Picosecond laser

Picosecond laser

…Stop laser Stops the laser emission (inside the laser head) ?SUBNET STR -- Get the Ethernet subnet Returns the Ethernet subnet SUBNET -- -- Set the subnet when DHCP is disabled Sets the subnet when DHCP is disabled ?TATT FLT % Get transmission Returns the transmission of the variable attenuator TATT…

Powered by Site Search powered by SLI Systems

Call 1-800-227-8840


Outside the U.S. 1-408-764-4983

Coherent has locations across the globe that are available to provide support for any product, service or inquiry.

Visit our Contact Page to connect with any of our global sites.


Corporate Headquarters
Coherent Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054 USA

email: tech.sales@coherent.com

Send Us a Message

Please Read Before Continuing

Risk factors: Except for the historical information contained here, many of the matters discussed in this Web site are forward-looking statements, based on expectations at the time they were made, that involve risks and uncertainties that could cause our results to differ materially from those expressed or implied by such statements. These risks are detailed in the “Factors That May Affect Future Results” section of our latest 10-K or 10-Q filing. Coherent assumes no obligation to update these forward-looking statements.


I have read the terms and conditions