Search
Superior Reliability & Performance

  • Lasers and Laser-based Systems
  • Laser Measurement and Control
  • Precision Optics
  • Related Accessories
1 - 10 of 195 Search Results for water chiller

1pdf document  Laser Cooling Water Guidelines Best match in this PDF  |  All matches in this PDF
…Appendix A: Coherent Cooling Options. Closed-Loop Chiller Chillers have many of the same advantages of heat exchangers insofar as a fixed volume of water is recirculated through the laser. Unlike heat exchangers, they do not require a second supply of water to carry off the heat generated in the laser system…
Related Searches: water chiller manual | water cooling | innova 300 manual

2Coherent Inc. Troubleshooting Clogged Water Flow of DPSS lasers
Water Flow For AVIA, Verdi and Vitesse Lasers * Ensure distilled water is used in the chiller. Do not use deionized water, or hard water. Deionized water is corrosive. Hard water contains dissolved minerals, which may eventually precipitate and clog small diameter fittings. Periodically replace the water
Related Searches: verdi operator's manual

300_Laser_Cooling.book  (PAGE 3 OF 34)
…........................................................11
Closed-Loop Chiller .......................................................................................................11
Evaluating an Existing Water System............................................................12
Problems…
Related Searches: water cooling | laserpure 20 manual | chiller

4pdf document  DIAMOND E1000 premanual Best match in this PDF  |  All matches in this PDF
…Cooling [ ] Chiller installed and operational (loop test OK) [ ] Coolant is a mixture of water and corrosion inhibitor [ ] 30 µm particle filter installed at laser head inlet [ ] Shut-off valves installed (optional, recommended) [ ] 5/8" ID or greater hose between the laser and chiller [ ] Required…
Related Searches: oem manual | water chiller manual | coherent laser cables | rf module

5pdf document  Verdi V8-V10 Preinstallation Best match in this PDF  |  All matches in this PDF
…Position the chiller in the operating position. Fill and prepare the chiller in accordance with the chiller user's manual. 3. Cut the user-supplied cooling water lines to the appropriate lengths and use the water line hardware (Figure 1-1, item 9) to connect the riser/heat sink to the chiller (Figure 1…
Related Searches: closed loop chiller | verdi v10 manual | verdi 8 | interlock

6Verdi_preinstall.book  (PAGE 12 OF 18)
chiller in the operating position. Fill and prepare
the chiller in accordance with the chiller user's manual.
3. Cut the user-supplied cooling water lines to the appropriate
lengths and use the water line hardware (Figure 1-1, item 9) to
connect the riser/heat sink to the chiller
Related Searches: verdi laser manual

7pdf document  Verdi V18 Preinstallation Best match in this PDF  |  All matches in this PDF
…Position the chiller in the operating position. Fill and prepare the chiller in accordance with the chiller user's manual. 3. Cut the user-supplied cooling water lines to the appropriate lengths and use the water line hardware (Figure 1-1, item 9) to connect the riser/heat sink to the chiller (Figure 1…
Related Searches: verdi 18 | verdi v18 | fap manual | external interlock

800_HighLight_4000_Pre.book  (PAGE 23 OF 83)
…69-103 kPa (10-15 psi)
Chiller Coolant De-ionized water
Cooling Capacity 7 kW (24 kBtu/hr)
Chiller Water Capacity(4)
95 liters (25 gal)
Chiller Pressure (maximum) 448 kPa (65 psi)
Chiller Flow Rate (minimum) 23 lpm (6.1 gpm)
Chiller Water Temperature Set-point 25°C…

900_Laser_Cooling.book  (PAGE 17 OF 34)
…Cooling
Options.
Closed-Loop
Chiller
Chillers have many of the same advantages of heat exchangers
insofar as a fixed volume of water is recirculated through the laser.
Unlike heat exchangers, they do not require a second supply of water
to carry off the heat generated in…
Related Searches: chiller | water cooling

10pdf document  HighLight 4000L Preinstallation Manual Best match in this PDF  |  All matches in this PDF
…or PM5K-200) · Water-cooling system for the thermal detector head Utility Requirements and Installation 49 Each time the unit is set-up for use, adhere to the following procedures: Laser Head Set-up 1. Verify the length for the waters lines and cables from the SCU and system chiller. Place all of the…
Related Searches: laser wire stripper | evolution manual | water wheel | manual


Page 1 2 3 4 5 6 7 8 9 10 11>> of 20 | Next